OPTIM FR P&P
Automatic capacitor banks with detu...
OPTIM FR P&P 60Hz
OPTIM FRF
Fixed capacitors with detuned react...
OPTIM FRM
Fixed capacitors with detuned reac...
Floor-mounted
OPTIM FR4 P&P
OPTIM FR6 P&P
OPTIM FR8 P&P
OPTIM FR10 P&P
OPTIM FR12 P&P
OPTIM FRS P&P
25
31.25
37.5
43.75
50
60
62.5
75
90
100
105
120
150
175
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
30
40
87.5
125
140
160
180
220
240
262.5
280
320
337.5
360
375
412.5
440
480
487.5
525
675
825
3
4
5
6
7
8
9
10
11
12
Detuned capacitor bank
R54R64.
OPTIM FRS-P&P-31,25-440, Detuned capacitor bank;Cable section (mm2): 10;Nr steps: 3;kvar (400 V): 26;kvar (440 V): 31,25;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 6,25 + 2 x 12,5;Use voltage (V): 440
R54R74.
OPTIM FRS-P&P-43,75-440, Detuned capacitor bank;Cable section (mm2): 25;Nr steps: 3;kvar (400 V): 36;kvar (440 V): 43,75;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 6,25 + 12,5 + 25;Use voltage (V): 440
R54R81.
OPTIM FRS-P&P-62,5-440, Detuned capacitor bank;Cable section (mm2): 35;Nr steps: 3;kvar (400 V): 52;kvar (440 V): 62,5;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 12,5 + 2 x 25;Use voltage (V): 440
R54R88.
OPTIM FRS-P&P-90-440, Detuned capacitor bank;Cable section (mm2): 70;Nr steps: 4;kvar (400 V): 74;kvar (440 V): 90;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 2 x 15 + 2 x 30;Use voltage (V): 440
R54R92.
OPTIM FRS-P&P-105-440, Detuned capacitor bank;Cable section (mm2): 70;Nr steps: 4;kvar (400 V): 87;kvar (440 V): 105;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 15 + 3 x 30;Use voltage (V): 440
R54R95.
OPTIM FRS-P&P-120-440, Detuned capacitor bank;Cable section (mm2): 95;Nr steps: 4;kvar (400 V): 99;kvar (440 V): 120;Aut.Switch (A): -;Man.Switch (A): Included;Composition: 4 x 30;Use voltage (V): 440
Detuned capacitor bank ,60 Hz
R54RBN.
OPTIM FRS P&P-25-240-60Hz, Detuned capacitor bank 60 Hz; Frequency (Hz): 60 Hz; kvar (240 V): 25; Aut.Switch (A): 3 x 100; Composition: 2x5+10; Mounting: Floor-mounted; P%: 7
R54RBP.
OPTIM FRS P&P-30-240-60Hz, Detuned capacitor bank 60 Hz; Frequency (Hz): 60 Hz; kvar (240 V): 30; Aut.Switch (A): 3 x 125; Composition: 3x10; Mounting: Floor-mounted; P%: 7
R54RBS.
OPTIM FRS P&P-40-240-60Hz, Detuned capacitor bank 60 Hz; Frequency (Hz): 60 Hz; kvar (240 V): 40; Aut.Switch (A): 3 x 160; Composition: 4x10; Mounting: Floor-mounted; P%: 7
R54SF0.
OPTIM FR4 P&P-37,5-240-60Hz, Detuned capacitor bank 60 Hz; Frequency (Hz): 60 Hz; kvar (240 V): 37,5; Aut.Switch (A): 3 x 125; Composition: 3x12,5; Mounting: Floor-mounted; P%: 7