Reclosing protection relays and residual current reclosing with WGC external transformer

RGU-10 RAL

RGU-10 RAL, Reclosing residual current relay

Code: P24622.

  • IΔn (A): 0,03 … 30 A
  • Delay: 0,02...10 s, INS, SEL
  • Nr. reclosures: Programmable
  • Breaking element: Contactor
  • Type of protection: Type A

INFORMATION

Description

Electronic residual current protection relay, used to connect the external toroidal transformers of the WG / WGS / WGC Series. Self-reclosing with a programmable residual current trip. Superimmunized type A Relay, with high frequency current filtering and high immunity. Monitoring in TRMS The backlight display shows the following information:

  • Adjustment values
  • Instantaneous leakage current
It has two independent outputs:

  • Trip relay
  • End-of-reclosing-sequence interlocking relay
Other features:

  • External input for remote control functions (230 V~)
  • Automatic test of the connection and external transformer status
  • Optional RS-485 Communications: type RGU-10C RAL
  • Reduced dimensions: 3 modules
  • Assembly on DIN rail 46277 (EN 50022).
  • Optional assembly on 72 x 72 panel with accessory M5ZZF1.

Applications

The RGU-10 RAL relays associated to a meter allow the automatic reclosing after a trigger, thus offering the most adequate solution for public lighting, cash machines, refrigeration chambers, traffic lights, etc. Its design characteristics guarantee maximum security and continuity of the electrical service, avoiding unwanted tripping.

SPECIFICATIONS

AC power supply
Nominal voltage
110 - 230 V~ (± 20 %)
Frequency
50/60 Hz
Consumption
6 VA
External reset input for tripping
Maximum voltage
230 Vca
Type
Optocoupled
Maximum power
0,7 W
Digital relay outputs
Nominal voltage
250 V ~
Nominal current
6 A ~
Maximum current
10 A ~
Nominal load in AC
2500 VA
User interface
Display type
Backlit LCD
Environmental characteristics
Working temperature
-10 … +50 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 20 (terminals), IP 41 (front)
Mechanical characteristics
Fastening
DIN rail
Weight (kg)
0,231
Size (mm) width x height x depth
52.5 x 85 x 67.9 (mm)
Protection
Circuit breaker type
Contactor
Differential protection
Transformer
External, WG (WG/WGS/WGC) series
Type
Type A ultra-immunised
Sensitivity (I∆n), A
0,03 … 3 / 5-10-30 (Setup)
Delay time (t∆)
0,02 … 10 s
Standards
Standards
IEC 61008-1, IEC 60755, IEC 255-5
Electrical safety, Maximum height (m)
2000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

User's manual
3D
Diagram connection
Datasheet
CE-certified