Control module for PV measurement using Hall effect sensor

STM-CH-LoRa-F915

STM-CH-LoRa-F915, LoRa control module with Hall effect transformers for measuring current, 915 MHz frequency,

Code: E82CH20020000DISCONTINUED

    INFORMATION

    Description

    STM-H is an intelligent analyser with up to 32 channels and Hall effect sensors. Specifically designed for monitoring photovoltaic strings, the STM ensures maximum photovoltaic field performance thanks to its high measurement accuracy. The solution comprises various modules:

    STM-CH: Module equipped with the intelligence to calculate power, compare string performance, detect reverse currents, etc.

    It also includes:

    • Voltage input (1.500 V dc)
    • 4 potential-free digital inputs
    • 1 analogue input, 0/4...20 mA
    • 1 input for Pt100 or Pt1000
    • Wireless LoRa communications module
    STM-SH: Current measuring module with up to 16 measuring channels of up to 25 A, 16 channels of up to 50 A, or 8 channels of 200 A each. Up to 2 STM-SH modules can be connected to provide 32 channels of 25/50 A or 16 channels of 100 A. Its modularity, installation flexibility, intelligence and robustness make the STM-H the perfect device for monitoring the correct operation of the photovoltaic field.

    Applications

    Monitoring photovoltaic strings in solar farms and self-consumption installations.

    SPECIFICATIONS

    DC power supply
    Nominal voltage
    24 V ±10%
    Consumption
    4.2 W
    Installation category
    CAT III 1000 V
    Voltage measurement circuit
    Voltage measuring range
    10...1500 Vdc
    Input impedance
    3200 kΩ
    Minimum measurement voltage (Vstart)
    10 V
    Installation category
    CAT III 1000 V
    Maximum input voltage consumption
    0,5 mA
    Current measurement circuit
    Phase current measuring range
    25 A channel, 2 ... 25 Adc 50 A channel, 2 ... 50 Adc 200 A channel, 2 ...100 Adc
    Impedance
    300 kΩ
    Installation category
    CAT II 1000 V
    Start-up current (Ist)
    2 A
    Digital inputs
    Quantity
    4
    Type
    Potential free contact
    Input/output insulation
    Optoisolated
    Maximum short-circuit current
    6 mA
    Maximum open circuit voltage
    24 V
    Analogue inputs
    Measurement type
    Current
    Nominal range
    0...20 mA / 4...20 mA
    Nominal input range
    0...20 mA / 4...20 mA
    Accuracy
    ± 0,1 mA
    Input impedance
    150 Ω
    Maximum allowable neutral current
    20 mA
    User interface
    LED
    7
    Environmental characteristics
    Working temperature
    -20...70 ºC
    Storage temperature
    20...80 ºC
    Relative humidity (without condensation)
    95%
    Protection class
    IP 00
    Installation, location, position.
    2000 m
    Mechanical characteristics
    Envelope
    Self-extinguishing V0 plastic
    Fastening
    DIN rail
    Weight (kg)
    0,19
    Size (mm) width x height x depth
    100 x 127.8 x 72.35 (mm)
    Input
    Type
    Pt100/1000
    Range
    -25 … 100ºC
    Resolution
    ±0,1 mA
    Accuracy
    ± 3ºC
    Standards
    Standards
    EN 61000-6-2, EN 61000-6-4, EN 61010-1, EN 61010-2-30
    Electrical safety, Installation category
    Protection against electric shock: Double class II insulation

    DIMENSIONS

    CONNECTIONS

    VIDEOS

    DOWNLOADS

    Technical guide
    Dimensions
    Diagram connection
    Datasheet
    Configuration guide
    Presentation

    ACCESORIES