Portable power analyzer with recording of quality events and transients

,

Code:

    SPECIFICATIONS

    AC power supply
    Nominal voltage
    100…240 Vc.a.(Adaptador de alimentación de c.a.)
    Frequency
    47…63 Hz
    Consumption
    22…28 VA
    Installation category
    CAT II 300 V
    Auxiliary battery power supply
    Battery type
    Litio (3,7 Vc.c.)
    Capacity
    3700 mAh
    Load time
    6 h
    Load temperature
    0 … 40 °C
    Autonomy
    2 h (without 3G), 50 min (with 3G)
    Powered by charger, adapter
    Output voltage
    9 Vc.c.
    Maximum power
    18 W
    Battery specification
    Type
    Litio
    Voltage
    3 Vc.c.
    Performance-guarantee
    10 años
    Capacity
    220 mAh
    Memory
    Type
    FAT 32
    Write time
    1s, 1m, 5m, 15m, 1h, 1d
    Voltage measurement circuit
    Frequency measuring range
    45…65 Hz
    Input impedance
    2,4 MΩ
    Minimum measurement voltage (Vstart)
    10 V ac
    Consumption
    0,15 VA
    Installation category
    CAT III 600 V
    Sampling frequency
    45…65 Hz
    Current measurement circuit
    Nominal current (In)
    Depending on the clamp
    Phase current measurement
    Transformadores con salida 0,250 A ó 0,333 V
    Phase current measuring range
    1…200 % In
    Maximum pulse current
    3 x In A
    Minimum current measurement
    Depending on the clamp
    Maximum input current consumption
    0,0004 VA
    Installation category
    CAT III 600 V
    Specific technical characteristics of current sensors
    Measurement range
    1…500 A
    Linearity
    0,2 % (3…120 % In)
    Measurement accuracy
    Phase voltage measurement
    Class 0.2 0,2 (10…1000 VF-N c.a.) (IEC 61557-12)
    Phase current measurement
    class 0,2 (1…200 % In) (IEC 61557-12)
    Frequency measurement
    Class 0,1 (45…65 Hz)
    Active power measurement (kW)
    class 0,5 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
    Apparent power measurement (kVA)
    class 0,5 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
    Reactive power measurement (kvar)
    Class 1 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
    Active energy measurement (kWh)
    Class 0,5S (IEC 62053-22)
    Reactive energy measurement (kvarh)
    Class 1 (IEC 62053-23)
    Power factor measurement
    Class 0.5 (IEC 61557-12)
    Voltage THD
    Class 0.5 (IEC 61557-12)
    Voltage harmonics (THD)
    (up 50th) Class 1 (IEC 61000-4-7)
    Current harmonics (THD)
    (up 50th) Class 1 (IEC 61000-4-7)
    Pinst. Flicker
    3 % (IEC 61000-4-15)
    Pst Flicker
    5 % (0,2 … 10Pst) (IEC 61000-4-15)
    Voltage unbalance (Kd)
    Class A (IEC 61000-4-30)
    Voltage asymmetry (Ka)
    Class A (IEC 61000-4-30)
    Current unbalance (Kd)
    Class A (IEC 61000-4-30)
    Current asymmetry (Ka)
    Class A (IEC 61000-4-30)
    Wireless communication
    Technology / Type
    Wi-Fi
    Band
    2,4 GHz.
    Standards
    Standards
    Recycling European Directive 2002/96/EC, EN 61326-1, IEC 61010-1, 3rd Edition
    Certifications
    CE
    Electrical safety, Maximum height (m)
    2000
    Electrical safety
    Insulation
    Double-insulated electric shock protection class II (IEC 61010-1)

    DIMENSIONS

    CONNECTIONS

    VIDEOS

    DOWNLOADS

    ACCESORIES