Portable power analyzers

AR5L-1M

AR5L-1M, Portable power analyzers

Code: M80111.

  • Measuring current Channels: 4
  • Device: AR5L
  • Modules: 48 x 48

INFORMATION

Description

  • Measures all the main electrical parameters of an electrical network
  • Provides TRMS readings
  • Built-in energy meter
  • With 4 voltage and 4 current channels
  • Autotrigger can be adjusted based on the parameters desired
  • Languages: Spanish and English
  • Large, LCD backlit display
  • CAT III 600 V (EN 61010). UL certified
  • Display up to 30 electrical parameters on screen
  • Small and lightweight, only 800 g.
  • Independent files for each measurement
  • Includes powerful analysis software: POWER VISION PLUS
  • Adjustable via the menu
  • Up to 8-hour battery life
  • RS-232 communication with PC
  • Automatic clamp detection
  • Automatic selection of parameters to save
  • Calculation of time remaining until memory full
  • Linear or rotary memory (depending on configuration)

Applications

Complete study of an installation, in which the analyzer is capable of recording different parameters: harmonics, disturbances, meter verifications, transitory, flickers, etc.

SPECIFICATIONS

AC power supply
Consumption
15 VA
Frequency
50…60 Hz
Nominal voltage
100…240 Vc.a./12 Vc.c. (a través de alimentador externo)
Mechanical characteristics
Size (mm) width x height x depth
128 x 221 x 63 (mm)
Weight (kg)
2,8
Environmental characteristics
Relative humidity (without condensation)
80% para temperaturas inferiores a 31 ºC, disminuyendo linealmente hasta 50% a 40 ºC
Working temperature
0 … +40 °C
Standards
Certifications
UL, VDE
Electrical safety, Maximum height (m)
≤ 2000
Electrical safety, Installation category
CAT III - 600 V, IEC 61010
Standards
IEC 60664, IEC 61010, IEC 61036, VDE 0110 , UL 94, IEC 61000-3-2(1995), IEC 61000-3-3(1995), IEC 50081-2(1993), EN 55011 (1994): Conducted (EN 55022-Class B), Radiated (EN 55022-Class A), EN 50082-2 (1995), IEC 61000-4-8 (1995), IEC 61000-4-2 (1995), UNE-ENV 50141
Current measurement circuit
Phase current measuring range
According to clamp
Measurement units
Automatic scale change
Transformation ratio
Programmable
Voltage measurement circuit
Sampling frequency
45…65 Hz
Voltage measuring range
45…65 Hz
User interface
Resolution of the display
160 x 160 pixels (Backlight)
Display type
LCD
Measurement accuracy
Phase current measurement
0,5% ±2 digit
Reactive power measurement (kvar)
1% ±2 digit
Active power measurement (kW)
1% ±2 digit
Phase voltage measurement
0,5% ±2 digit

DIMENSIÓN

VÍDEOS

DESCARGAS

User's manual
Datasheet

ACCESORIOS

TAMBIÉN TE PUEDE INTERESAR