PRIME PLC Concentrator

Compact DC-S 4I

Compact DC-S 4I, PRIME PLC Concentrator

Code: Q46220.

  • 2nd transformer connection: No
  • Homologation: Naturgy
  • Communications: PRIME
  • Digital inputs: 4
  • LV supervisor: 1

INFORMATION

Description

The COMPACT DC concentrator is the device used to manage and read three-phase and single-phase power meters connected to the same low-voltage network using PRIME communications.
Typically located in the transformer substation, the COMPACT DC concentrator provides telemanagement features for the meters, whether reading the information they provide, or executing the actions that can be applied to this type of device, such as modifying tariffs, actuating the circuit breaker, etc.
COMPACT DC has an indirect three-phase meter with low-voltage monitoring functions, depending on the model.
The device features PRIME PLC communications, an Ethernet port and digital inputs.

SPECIFICATIONS

AC power supply
Installation category
CAT III 300V
Consumption
12 … 27 VA
Frequency
50 / 60 Hz
Nominal voltage
110 … 230 V~ ±20 %
Mechanical characteristics
Size (mm) width x height x depth
203 x 120 x 130 (mm)
Envelope
Self-extinguishing V0 plastic
Fastening
DIN rail
Weight (kg)
1,1
Environmental characteristics
Protection class
IP40
Relative humidity (without condensation)
5 … 95 %
Working temperature
-25 … +70 ºC
Current measurement circuit
Installation category
CAT III 600V
Nominal current (In)
5 A
Phase current measuring range
2 mA … 10 A
Maximum input current consumption
0.02 VA
Maximum pulse current
20 x In (< 1s)
Minimum current measurement
2 mA
Voltage measurement circuit
Installation category
CAT III 600V
Input impedance
800 KΩ
Frequency measuring range
45 … 65 Hz
Voltage measuring range
127/220 … 230/400 V~ ±20 %
Maximum input voltage consumption
0.07 VA
Minimum measurement voltage (Vstart)
10 V~
Standards
Electrical safety, Maximum height (m)
2000
Standards
UNE-EN 61000-4-2, UNE-EN 61000-4-3, UNE-EN 61000-4-4, UNE-EN 61000-4-5, UNE-EN 62052-11, IEC 61010
User interface
LED
15 indication LEDs / 1 LED (20000 imp / kWh) / 1 LEDs (20000 imp / kVArh)
Digital inputs
Input/output insulation
10 kV @1min
Quantity
4
Type
Short circuit (Vmax = 12.5 Vdc, Imax = 15 mA)
Measurement accuracy
Phase current measurement
1%
Reactive energy measurement (kvarh)
Class 2
Active energy measurement (kWh)
Class B (1)
Phase voltage measurement
1%

DIMENSIÓN

VÍDEOS

DESCARGAS

User's manual
Technical guide
Datasheet
Catalogue
CE-certified

ACCESORIOS

TAMBIÉN TE PUEDE INTERESAR