URBAN-WB SLAVE CCS1

URBAN-WB SLAVE CCS1, DC Car park boxes

Code: V20741.CONSULTAR DISPONIBILIDAD

  • Communications: Ethernet
  • Output type: 153 ... 920 Vcc - 70 A - 25 kW
  • Connector type: CCS Combo 1 [CC]
  • Grid type: Three-phase
  • Charge mode: 4
  • No. Sockets: 1
  • Earth leakage protection: Type B

SPECIFICATIONS

AC power supply
Nominal voltage
400 V ~ (± 10 %) (480 V ~ bajo demanda)
Frequency
50 / 60 Hz
Input intensity
39 A
Efficiency
94%
Power factor
> 0,98
Type of network
3Ph + N + GND
Electrical characteristics
Voltage
150 … 920 Vdc
Max. output power (kW)
25 (cc)
Surge protection (DSP)
Optional
Max. output intensity (A)
0 … 70 cc
Cable: Connector type
CCS Combo 1 (5.5-m cable length)
No. of charges
1
Charging mode
Mode 4
Overcurrent protection
MCB curve C (50 A)
Communication Network
Technology / Type
Ethernet 10/100 Base TX (TCP/IP)
Protocol
OCPP
User interface
LED
RGB color charge indicator
Environmental characteristics
Working temperature
-35 … +45 ºC
Storage temperature
-40 … +60 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 54 / IK10
Mechanical characteristics
Envelope
Stainless steel
Fastening
Wall-mounted
Noise
< 55 dB
Weight (kg)
56
Size (mm) width x height x depth
382 x 984 x 236 (mm)
Protection
Safety relay type (class)
RCD B
Features / performance
Energy measurement
Meter for measuring alternating electrical energy according to UNE-EN 50470
Output 1
Network type
DC
Connector type
CCS Combo 1 (CC)
Maximum power
25 kW
Voltage range
150-920 Vcc
Maximum current
70 A
Standards
Standards
IEC 61851-1, IEC 61851-22, IEC 61851-23, IEC 62196-1, IEC 62196-2, IEC 62196-3, CHAdeMO Certified, CCS (DIN 70121, ISO 15118)
Certifications
CE
Electrical safety, Installation category
CAT III 300 V
Electrical safety
Insulation
Double-insulated electric shock protection class II (IEC 61010)

DIMENSIONS

CONNECTIONS

VIDEOS