Home manager for EV recharging

Genion One MC

Genion One MC, Genion One, Home manager for charging vehicles

Code: V40702.COMING SOON

  • Protocol: Modbus RTU | TCP | MQTT
  • Nr Sensors: MC1-20-50/100/150A
  • Communications: RS-485 | Ethernet | Wi-Fi

INFORMATION

Description

Energy flow manager for home installations with electric vehicle chargers and self-supply. Compatible with every single-phase eHome Link models and with any solar inverter on the market. Genion One automatically manages the net hourly metering, feeding its energy into the grid when it is not generating enough and subsequently consuming this electricity.

It includes a web application to monitor and control the installation via Wi-Fi from any mobile device. Thanks to the installation wizard, you can automatically set up the number of electrical vehicle chargers and current transformers in the home.

Genion One has 3 modes of electricity flow management:

  • Just Green: Charges the electric vehicle at no cost using only excess solar power.
  • Smart Mix: Charges intelligently based on the configurations defined for each time period.
  • Boost: Charges at 100% of the available power regardless of the programmed schedule.

Applications

Genion One focuses on home use, making it the ideal complement for our eHome Link. It is also easy to install and start up.
This product is specially designed for installations with self-supply systems and home charging points.

SPECIFICATIONS

Auxiliary battery power supply
Autonomy
2 h (without 3G), 50 min (with 3G)
AC power supply
Installation category
CAT II 300 V
Consumption
8,8 …10,5 VA
Frequency
47 … 63 Hz
Nominal voltage
85 … 264 V~
Mechanical characteristics
Size (mm) width x height x depth
105 x 88.5 x 48 (mm)
Envelope
Polycarbonate UL94 - Self-extinguishing V0
Cable gauge at input and output terminals
1,5 mm2
Fastening
DIN rail 46277 (EN 50022)
Weight (kg)
0,15
Environmental characteristics
Protection class
IP 20
Relative humidity (without condensation)
5…95 %
Storage temperature
-25…+75 °C
Working temperature
-20…+50 °C
Current measurement circuit
Installation category
CAT III 600 V
Nominal current (In)
Depending on the clamp
Phase current measuring range
1…200 % In
Maximum input current consumption
0,0004 VA
Maximum pulse current
3 x In A
Minimum current measurement
Depending on the clamp
Voltage measurement circuit
Installation category
CAT III 600 V
Sampling frequency
45…65 Hz
Input impedance
2,4 MΩ
Voltage measuring range
45…65 Hz
Nominal voltage
230 V ~ (f-N) / 480 V ~ (F-F)
Minimum measurement voltage (Vstart)
10 V ac
Communications
Band
2,4 GHz.
Protocol
Modbus RTU, Modbus TCP, MQTT
Type
Ethernet / RS-485 / Wi-Fi
Speed
Ethernet 10 /100 BT (Mbit/s), RS-485: 9600 … 115200 bps
Standards
IEEE 802.11 b / g / n
Standards
Electrical safety, Maximum height (m)
2000
Electrical safety, Installation category
CAT III 300 V
Standards
Recycling European Directive 2002/96/EC, EN 61326-1, UL 61010-1, 3rd Edition, 2012-05-11, IEC 61010-1, 3rd Edition
Electrical safety
Insulation
Double-insulated electric shock protection class II (IEC 61010)
Memory
Type
PSRAM (8 MB) & SPI Flash (16 MB)
Digital transistor outputs
Type
Opto MOSFET
Maximum current
90 mA
Measurement accuracy
Current asymmetry (Ka)
Class A (IEC 61000-4-30)
Voltage asymmetry (Ka)
Class A (IEC 61000-4-30)
Current unbalance (Kd)
Class A (IEC 61000-4-30)
Voltage unbalance (Kd)
Class A (IEC 61000-4-30)
Frequency measurement
Class 0,1 (45…65 Hz)
Phase current measurement
class 0,2 (1…200 % In) (IEC 61557-12)
Reactive energy measurement (kvarh)
Class 1 (IEC 62053-23)
Reactive power measurement (kvar)
Class 1 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
Active energy measurement (kWh)
Class 0,5S (IEC 62053-22)
Active power measurement (kW)
class 0,5 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
Power factor measurement
Class 0.5 (IEC 61557-12)
Current THD
Class 1 (IEC 61000-4-7)
Voltage THD
Class 1 (IEC 61000-4-7)
Phase voltage measurement
Class 0.2 0,2 (10…1000 VF-N c.a.) (IEC 61557-12)
Pinst. Flicker
3 % (IEC 61000-4-15)
Pst Flicker
5 % (0,2 … 10Pst) (IEC 61000-4-15)
Current harmonics (THD)
(up 50th) Class 1 (IEC 61000-4-7)
Voltage harmonics (THD)
(up 50th) Class 1 (IEC 61000-4-7)

DIMENSIÓN

VÍDEOS

DESCARGAS

Datasheet
Catalogue

ACCESORIOS