Reclosing residual current relay for motorized circuit breakers

RGU-10 MT

RGU-10 MT, Reclosing residual current relay

Code: P24642.

  • IΔn (A): 0,03 … 30 A
  • Delay: 0,02...10 s, INS, SEL
  • Nr. reclosures: Programmable
  • Time betwen reclosures: Programmable
  • Breaking element: RECmaxMP | MT-FDE

INFORMATION

Description

Electronic residual current protection relay of the WGC series connected to the external toroidal transformers of the WG / WGS / WGC series. It is connected to a motorized circuit breaker of the MT series or similar, as a circuit breaker. The self-reclosing can be programmed by residual current and/or circuit breaker trip. Super-immunised type-A relay with high-frequency current filtering and high immunity. True root mean square (TRMS) measure.

 The backlit display shows the following information:

  • Adjustment values
  • Instantaneous leakage current

 Features two independent outputs:

  • Trip relay
  • Interlocking relay for end of reclosing sequence

 Other features:

  • External input for remote-control functions (230 V~)
  • Automatic test of the connection and external transformer status
  • Optional RS-485 communication: type RGU-10C MT
  • Compact size: 3 modules
  • Assembly on DIN 46277 rail (EN-50022).

Applications

The RGU-10 MT relays associated with the transformers of the WGC series enable smart residual current protection. These are used jointly with an MV or similar circuit breaker to enable self-reclosing after a trip (circuit breaker and residual current reclosing), offering a very good solution for street lights, ATMs, refrigerating chambers, etc. Their design features guarantee maximum security and electrical service continuity, avoiding unwanted tripping.

SPECIFICATIONS

AC power supply
Nominal voltage
230 V~ (± 20 %)
Frequency
50/60 Hz
Consumption
6 VA
External reset input for tripping
Type
Non-optocoupled, voltage-free
Digital relay outputs
Nominal voltage
250 V ~
Nominal current
6 A ~
Maximum current
10 A ~
Nominal load in AC
2500 VA
Mechanical life
10 x 106
User interface
Display type
Backlit LCD
Environmental characteristics
Working temperature
-10 … +50 ºC
Ambient temperature
-40 … +85 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 20 (terminals), IP 41 (front)
Mechanical characteristics
Fastening
DIN rail
Weight (kg)
0,242
Size (mm) width x height x depth
52.5 x 85 x 67.9 (mm)
Protection
Circuit breaker type
Motorised circuit breaker (with and without coil)
Differential protection
Transformer
External, WG / WGS series
Type
Type A ultra-immunised
Sensitivity (I∆n), A
0,03 … 3 / 5-10-30 (Setup)
Delay time (t∆)
0.02 … 10 s - Inverse curve: SEL/INS
Standards
Standards
IEC 61008-1, IEC 60755
Electrical safety, Maximum height (m)
2000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

User's manual
Technical guide
3D
Diagram connection
Datasheet
CE-certified

ACCESORIES