Type B residual current protection

RGU-10B

RGU-10B, Residual current relay type B

Code: P11951.

  • Módules: 3
  • Pre-alarm relay: Yes
  • Nº relays: 1
  • IΔn (A): 0,1…3 A
  • Power supply (Vac): 230 Vac
  • Delay: 0,1 … 10 s
  • Mounting: DIN rail

INFORMATION

Description

Electronic residual current current protection and monitoring relay (IEC 62020) compatible with the protection transformers of the WGC-TB series. The RGU-10B is the most complete system for monitoring and controlling electrical insulation of type-B installations (IEC 60755).

  • Electronic relay with relay output.
  • Measures in AC, DC or mixed current, type B (IEC 60755)
  • Measures the intensity of the current by connecting to an residual current transformer of the WGC-TB
  • Programmable with backlit LCD display:
    • Trip current (red display when tripped)
    • Parameter programming
    • Instantaneous leakage current
    • Disconnection of external transformer
  • Status signalling via 2 LEDs
  • Features two independent programmable outputs (main and prealarm).
  • Includes a remote-control input.
  • Assembly on DIN 46277 rail (EN 50022), 3 modules.

Applications

Monitoring of the electrical insulation in:

  • Single or three-phase AC installations, AC installations with DC components or purely DC installations. With frequencies of up to 1 kHz.

Such as, for example:

  • Speed drives
  • UPS (Uninterruptible Power Supply systems)
  • Photovoltaic installations
  • Motor control devices, etc.

SPECIFICATIONS

AC power supply
Nominal voltage
230 V~ (± 20 %)
Frequency
50/60 Hz
Consumption
6 VA
External reset input for tripping
Maximum voltage
230 Vca ± 20%
Type
Optocoupled
Maximum power
0,7 W
Digital relay outputs
Nominal voltage
250 V ~
Nominal current
10 A ~
Maximum current
15 A ~
Nominal load in AC1
2500 VA
User interface
Display type
Backlit LCD
Environmental characteristics
Working temperature
-10 … +50 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 20 (terminals), IP 41 (front)
Mechanical characteristics
Fastening
DIN rail
Weight (kg)
0,28
Size (mm) width x height x depth
52.5 x 85 x 67.9 (mm)
Differential protection
Transformer
External, WGC-TB series
Type
Type B
Sensitivity (I∆n), A
0,1 … 3
Delay time (t∆)
0,1 … 10 s
Standards
Standards
IEC 60947-2 (M), IEC 62020, IEC 60755
Electrical safety, Maximum height (m)
2000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

User's manual
Technical guide
3D
Diagram connection
Datasheet
Presentation
CE-certified
Video Installation
Other Certificates
Catalogue
Leaflet

ACCESORIES