Control module for PV measurement using a shunt

STM-CP-LoRa-F915

STM-CP-LoRa-F915, LoRa control module with positive current measurement, 915 MHz frequency,

Code: E82CP20020000CONSULTAR DISPONIBILIDAD

    INFORMATION

    Description

    STM is smart analyser that supports up to 32 channels. Designed specifically to supervise photovoltaic strings, the STM allows for the maximum performance of the photovoltaic array thanks to its high measuring accuracy.
    The solution consists of different modules:
    STM-C: Smart module that is able to calculate powers, compare string performances, detect reverse currents, etc. It also features:

    • One 1,500 VDC input
    • Four voltage-free digital inputs
    • One analogue input 0/4...20 mA
    • One input for Pt100 or Pt1000
    • A LoRa wireless communications module
    STM-S: Current measurement module with 4 measurement channels of up to 42 A each. Up to 8 
    STM-S modules can be connected to obtain 32 channels.
    Its modularity, flexibility of installation, smart characteristics and robustness make the STM the perfect piece of equipment to supervise the correct operation of the photovoltaic array.

    Applications

    Supervision of photovoltaic strings in solar farms and self-consumption installations

    SPECIFICATIONS

    DC power supply
    Nominal voltage
    24 Vdc ± 10 %
    Consumption
    100 mA
    Voltage measurement circuit
    Nominal voltage
    1500 Vdc
    Digital inputs
    Quantity
    4
    Type
    Optoisolated voltage-free
    Maximum short-circuit current
    6 mA
    Analogue inputs
    Nominal range
    0/4...20 mA
    Accuracy
    ±0,1 mA
    Environmental characteristics
    Working temperature
    -20...+70ºC (continuous) -20...+80ºC (peak)
    Relative humidity (without condensation)
    5 … 95 %
    Mechanical characteristics
    Fastening
    DIN rail
    Weight (kg)
    0,21
    Input
    Type
    Pt100/1000
    Range
    -25 … 100ºC
    Resolution
    ±0,1 mA
    Accuracy
    ± 3ºC
    Standards
    Electrical safety, Installation category
    Category II Double-insulated electric shock protection class II

    DIMENSIONS