Beacon control equipment

TB-3

TB-3

Code: P30102.CONSULTAR DISPONIBILIDAD

  • Programmable power between 15 ... 225 W Control of one circuit (BEACON). Luminosity level controlled by means of a photocell (included with the equipment). 1 alarm relay for failure of circuit or photocell

INFORMATION

Description

The TB-3 type Beacon control system is in charge of the supervision, control and transmission of anomalies detected in the different Beacon components of the telephony transmission towers.

TB-3 Features:

  • Start-up control and measurement of the consumption of a single Beacon circuit: group of 1, 2 or 3 75W/230V or 15W/230Vac lamps.
  • Inputs for a twilight photocell. The photocell will be supplied with the unit and is connected with the corresponding terminals (+ and - inputs of the photocell).
  • Adjustments of the TB-3
    • Power of the 15 to 225 W lamp circuit.
    • Light level between 200 and 1000 lux.
  • Relay output used to signal alarms.

Applications

Simple unit used to control and supervise a simple Beacon circuit, in addition to the supervision of the photocell's operation.

SPECIFICATIONS

AC power supply
Nominal voltage
230 V~ ±20 %
Frequency
50 / 60 Hz
Digital relay outputs
Contact-coil insulation
2500 V~
Environmental characteristics
Working temperature
-10 … +50 ºC
Protection class
IP 20
Standards
Standards
IEC 60255-5, UNE 20801-2, UNE 20801-3, UNE 20801-4, UNE-EN 60730-1
Mechanical characteristics
Weight (kg)
0,99
Size (mm) width x height x depth
105 x 90 x 70 (mm)