Static Var Generator with multilevel technology, 50 / 60 Hz.

SVGm-4WF-069R-400

SVGm-4WF-069R-400, Static Var Generator with multilevel technology

Code: R4P4RC.

  • EMI filter: 1
  • kvar (280 V): 48.3
  • System: 4 wires, 230...400 V
  • kvar 400-440-480 V: 69
  • kvar (230 V): 40
  • Phase current: 100
  • Use voltage (V): 400

INFORMATION

Description

SVGm cabinet-type static var generators are the most accurate power factor correction solution in both unbalanced three-phase systems and installations with inductive and capacitive reactive power. They can be used in three-phase industrial, commercial or service installations, and they are not affected by the installation's harmonics. Much safer device with minimal maintenance. This product range features rack assembly in standard cabinets, designed to simplify installation.

The implemented characteristics and functions are as follows:

  • Power factor correction (inductive/capacitive) from 100 to 400 kvar (3W) and 69 to 276 kvar (4W) per cabinet.
  • The 100 kvar (3W) and 69 kvar (4W) rack-type module's compact dimensions make it easy to install in standard cabinets.
  • Multi-range voltage and frequency (50/60 Hz).
  • Harmonic current immunity.
  • Cos φ range from 0.7 inductive...to...0.7 capacitive.
  • Web-based performance monitoring.
  • Internal short-circuit protection.

If higher reactive power compensation capacity is required, up to 100 devices can be connected in parallel.

Applications

Ideal solution for individual loads or installations with numerous single-phase and three-phase loads, whether inductive or capacitive. Also, for installations whose load fluctuates over short time frames. Typical loads would be overhead cranes, welding equipment, lifts, drilling/shredding systems, data centres.

SPECIFICATIONS

AC power supply
Consumption
2070 W (Consumo máximo)
Frequency
50 / 60 Hz ± 5 %
Nominal voltage
208 … 400 V~ F-F (± 10 %)
Mechanical characteristics
Size (mm) width x height x depth
482.5 x 263 x 714.5 (mm)
Noise
< 60 dBA
Weight (kg)
55
Environmental characteristics
Working temperature
-10 … +45 ºC
Electrical characteristics
Maximum phase current
100 A (RMS)
Earthing system
TN, TT
Current measurement circuit
Consumption
1,5 VA por transformador
Transformation ratio
Transformer: 5/5A … 5000/5A
Standards
Electrical safety, Maximum height (m)
3000 (2000 m sin limitar prestaciones)
Standards
IEC 61000-6-4, UNE-EN 55011, IEC 61000-6-2, IEC 62477-1, IEC 61439-1, IEC 60721-3-3 (Indoor conditioned)

DIMENSIÓN

VÍDEOS

DESCARGAS

User's manual
Diagram connection
Configuration guide
Datasheet
Catalogue
CE-certified
Other Certificates