Motorized circuit breakers, 2 poles C curve

RECmax MP-C2-6

RECmax MP-C2-6, Motorized circuit breaker,2-pole C-curve

Code: P27110.

  • Poles: 2
  • In (A): 6 A
  • Curve: C

INFORMATION

Description

The RECmax MP series are motorized circuit breakers that can be linked remotely. They offer protection against short-circuits and overloads, and can also be used as a circuit breaker. After a disconnection caused by a circuit breaker, the switch can be reconnected by an external order. It has two inputs which, via voltage-free external signals, order the opening (input O) and subsequent closing (reclosing) of the circuit breaker (input I). It also features two single-contact outputs for signalling the status and the cause of the opening and closing of the circuit breaker (trip, manual/test).

Applications

The RECmax MP series are motorized circuit breakers that can be controlled remotely, suitable for any application in which remote control of connection/disconnection is required.

They are also used as circuit breakers linked to CIRCUTOR self-reclosing relays. They are an essential accessory for automatic circuit breaker and residual current reclosing and protection.

SPECIFICATIONS

AC power supply
Nominal voltage
230V ~ ± 30%
Frequency
50 / 60 Hz.
Consumption
4,5 VA
Installation category
CAT III 300 V
Digital relay outputs
Type
Simple contacts
Nominal voltage
230 V ~
Nominal current
0,25 A
Environmental characteristics
Working temperature
-20 … +70 ºC
Relative humidity (without condensation)
5 …95 %
Protection class
Motor: IP 40 (DIN 40050) / RECmax MP: IP 20
Mechanical characteristics
Envelope
Plastic V0 polycarbonate + GF
Fastening
DIN 46277 (EN 50022)
Weight (kg)
0,42
Size (mm) width x height x depth
79 x 110 x 83 (mm)
Motor
Nominal voltage
230 V ~ ± 30 %
Maximum voltage
420 V ~
Minimum voltage
90 V ~
On / off pulse time
> 10 ms / > 10 ms
Frequency (Hz)
50 / 60
Absorbed power
10 VA
Tripping / motor reclosure time
< 10 ms / < 1000 ms
Electrical life
> 20000 operations
Thermal-magnetic protection
V~ Breaking capacity (IEC 60947-2)
240 V ~
DC voltage breaking capacity (IEC 60947-2)
< 125 V
Number of mechanical / electrical manoeuvres
> 20000 / 10000
Minimum operating voltage UB min (V)
12 V ~
Nominal voltage
240 / 415 V ~
Nominal current In (A)
6
Trip curve, Type
C
Ultimate short-circuit breaking capacity (Icu) / service short-circuit breaking capacity (Ics), in DC (IEC 60947-2)
30 kA
AC ultimate short-circuit breaking capacity (Icu) (IEC 60947-2)
20 kA
Standards
Standards
IEC 60898, IEC 60947-2
Electrical safety, Maximum height (m)
2000

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

Technical guide
3D
Diagram connection
Datasheet
CE-certified
Product video
Catalogue
Leaflet

ACCESORIES

TAMBIÉN TE PUEDE INTERESAR