Partial consumption energy meters

CEM-D310 -MID

CEM-D310 -MID, Indirect three-phase energy meter with MID certification

Code: Q23602.

  • Módules: 4
  • Certification: MID
  • Transistor output: 1
  • System: Three-phase
  • Measure: Indirect
  • Measurement Range (V): 3x127(230)…3x230(400)V
  • Measurement Range (A): …/5A o …/1A

INFORMATION

Description

Three-phase electric energy meter with indirect measurement .../5 A and .../1 A (depending on model), featuring sealable terminals and optional communication via Modbus RS-485 and M-BUS protocols (depending on model). 

Main features include:

  • MID certification, modules B+D (depending on model).
  • Class 1 for active energy (Class B as per MID), Class 2 for reactive energy.
  • Compliant with EN 50470 (European MID standard) or IEC 62052-11 (international standard), depending on the model.
  • Compact size (4 DIN rail modules).
  • Resettable partial energy counter.
  • 1 programmable pulse output (depending on model).
  • 1 digital input for tariff control and pulse counting (depending on model).
  • Time-of-use tariff calendar.
  • Modbus RS-485 and M-BUS communications (depending on model).
  • Display of basic electrical parameters (V, A, kW, kWh, PF, etc.).

Applications

  • Meter for energy sub-metering.
  • Applications where certified MID meters are required for energy verification and billing.
  • Meter used to verify the energy invoiced by the electricity distributor.
  • Energy consumption reporting and connectivity with SCADA systems.
  • Energy and cost control in industrial processes.

SPECIFICATIONS

AC power supply
Nominal voltage
3 x 127/220 ... 3 x 230/400 V ~ ± 20 %
Frequency
50 … 60 Hz
Consumption
< 0.5 W, < 2 VA
Installation category
CAT III 300 V
Voltage measurement circuit
Nominal voltage
3 x 127/220 ... 3 x 230/400 V ~ ± 20 %
Current measurement circuit
Minimum current measurement
…/5 A (0.05A)
Reference current (Iref)
…/5 A (5A)
Transition current
0.250 A
Consumption
< 1 VA
Measurement accuracy
Active energy measurement (kWh)
Class B (UNE-EN-50470)
Reactive energy measurement (kvarh)
Class 2 (IEC 62053-23)
Digital transistor outputs
Type
Optocoupler
Maximum voltage
≤ 27 V
Maximum current
≤ 27 mA
Pulse output, time period (Ton / Toff)
Ton: 40 ms / Toff: 64.34 ms
User interface
Display type
LCD
Maximum value
4294967 kWh
LED
2 LED: kWh: 4000 imp/kWh, kvarh: 4000 imp/kvarh
Keyboard
2 Keys
Environmental characteristics
Working temperature
-40 ... +70 ºC
Storage temperature
-40 .. +85 ºC
Relative humidity (without condensation)
5 … 95 %
Protection class
IP 51 (instaled) IP 40 (terminal area)
Mechanical characteristics
Envelope
PC+ABS
Fastening
DIN rail (IEC 60715)
Weight (kg)
0,38
Size (mm) width x height x depth
71.5 x 90 x 74 (mm)
Standards
Standards
IEC-62053-21; IEC 62053-23; IEC 62053-52; IEC 62052-11; UNE-EN 50470-3; MID (EU Directive 2014/32/EU on Measuring Instruments Annex II, Module B

DIMENSIONS

CONNECTIONS

VIDEOS

CEM-D range | Energy meters for managing consumption and generation

DOWNLOADS

Technical guide
3D
Dimensions
Diagram connection
Datasheet
CE-certified
Product video
Catalogue