Automatic capacitor banks with rejection filters (static contactor), 50 Hz.

OPTIM FRE8-700-440

OPTIM FRE8-700-440, Static detuned capacitor bank

Code: R64K40.

  • Cable section (mm2): 3x150
  • Nr steps: 7
  • kvar (400 V): 579
  • kvar (440 V): 700
  • Optional circuit breaker (A) : 1250
  • Optional manual switch (A): 1600
  • Composition: 7 x 100
  • Use voltage (V): 440

INFORMATION

Description

The capacitor banks with detuned filters of the OPTIM FRE series have been designed for reactive energy correction in networks with fluctuating load levels, high harmonic presence and a risk of resonance.

The power variations are relatively quick (measured in milliseconds), and the operation is thus carried out by thyristors, which are connected to a voltage controller board, so that the connection and disconnection of the capacitor is carried out with zero voltage difference. Transients are prevented between the connection and disconnection of the steps, obtaining an immediate response to the load fluctuations.

Applications

The most common application is with individual loads or in installations where a quick compensation response is needed (e.g. welding units, motors for lifting units, lifts, etc.) and where the network has high harmonic content.

SPECIFICATIONS

Electrical characteristics
Losses (W)
< 0,5 W/kvar
Discharge resistance
75 V / 3 min
Surge
10 % 8 h over 24 h 15 % up to 15 min over 24 hours 20 % up to 5 min over 24 hours 30 % up to 1 min over 24 hours
Reinforcement voltage
440 V
Tolerance C
-5% / 10 %
Voltage
400 V (50 Hz) (other voltages on request)
Mechanical characteristics
Size (mm) width x height x depth
1500 x 1900 x 650 (mm)
Envelope
Sheet metal RAL 7035 Grey / RAL 3005 Garnet
Fastening
Vertical / Self-supporting
Ventilation
Natural or forced according to options
Weight (kg)
555
Environmental characteristics
Protection class
Marked on the label
Relative humidity (without condensation)
80%
Working temperature
Tª class D: Daily average: 45 ºC, annual average: 35 ºC, maximum: 55 ºC, minimum: -50 ºC
Current measurement circuit
Permanent overload
1,3 In
Transformation ratio
In / 5A
Standards
Electrical safety, Maximum height (m)
2000 m
Standards
UNE-EN 61921, UNE-EN 61439-1, UNE EN 60831
Features / performance
Components
CLZ capacitor Static switching unit on each stage, made up of static contactors (thyristors) Two-pole circuit breaker protection for capacitor bank and regulator operations. Reactive energy regulator of the Computer MAX-f Built-in thermostat on the heatsink for disconnecting the stage in the case of excessive temperatures (90 ºC) Detuned filters tuned to 189 Hz for protection against harmonics present in the network and for preventing resonance with harmonics of the 5th order or higher.
Optional
Manual switch on capacitor bank header Circuit breaker on capacitor bank header Circuit breaker + earth leakage protection on capacitor bank header Forced ventilation unit + thermostat Polycarbonate sheet for protection against direct contacts 400/230 V autotransformer
Protection
Element
Protection by stage by fuses with high cut-off power (APR). NH-00 series.