Reactors III for detuned static filters for FRE static switching bank

RBEZ-60-400

RBEZ-60-400, Reactor

Code: P73250.

  • L(mH): 1,89
  • For capacitor: CFB-46/74-6B
  • In (A): 51 A
  • Frequency (Hz): 50
  • kvar (400 V): 60
  • Losses: 252

INFORMATION

Description

CIRCUTOR has standardised the reactors of the REZ / RBEZ series for their use in static capacitor banks. The best operation of the unit requires the reactors to be connected within the triangle made p of the capacitor-reactor group. At the same power rating, the REZ / RBEZ reactors have a nominal current value that is 1.73 times lower and an inductance value that is 3 times higher than that in an RZ / RBZ reactor. There is a standard range of 400 V rejection reactors with p = 7%, with a resonance frequency of 189 Hz for 50 Hz networks (or 227 Hz on demand for 60 Hz networks). In addition, reactors can be manufactured on demand for static capacitor banks adapted to any value of the power rating, p%, voltage and frequency. REZ-type low-power reactors are built with low-loss plates and are coiled with copper wire. The connection is made using suitable terminals. In the case of higher power ratings, RBEZ reactors are used, with a magnetic plate nucleus and multiple air gaps, which offer excellent features and a low loss ratio. The coils are made with an aluminium band (or copper band, on demand). The input and output connections run through a busbar. Both REZ and RBEZ type reactors are impregnated with a varnish in a vacuum to increase insulation and reduce noise levels.

Applications

The rejection reactors of the REZ / RBEZ series have been specifically designed for use in static capacitor banks in installations with a high harmonic content. The reactors must be connected in series with each capacitor for adequate protection of the capacitors and the static operations module, and to avoid resonance effects in the installation.

SPECIFICATIONS

AC power supply
Frequency
50 Hz
Electrical characteristics
Voltage
400 V,on request: up to 1000 V
Insulation voltage, circuit
4 kV
L value (mH)
1.89
Tolerance L
± 5 %
Linearity (5% L)
1,8 In
Maximum transient current
2 In (1 min)
Permanent overload
1,17 In
Electrical characteristic
Overvoltage factor (p %)
7 % (189 Hz)
Environmental characteristics
Ambient temperature
-10 … +45 ºC
Thermal Class
"class F (+155 ºC) On request: class H (+180 ºC)"
Protection class
IP 00
Installation, location, position.
Inside
Mechanical characteristics
Envelope
Conductor type: Aluminium strip
Weight (kg)
30
Size (mm) width x height x depth
180 x 235 x 300 (mm)
Protection
Circuit breaker type
90°C NC thermostat
Standards
Standards
UNE-EN 60289, IEC 60076

DIMENSIONS

CONNECTIONS

VIDEOS

DOWNLOADS

Dimensions
Datasheet

ACCESORIES

TAMBIÉN TE PUEDE INTERESAR