Double Reed type frequencymeters

2HLC144 47-53Hz

2HLC144 47-53Hz

Code: M12942.CONSULTAR DISPONIBILIDAD

  • Frequencymeter
  • Accuracy: 0,5
  • Measure: 47...53 Hz
  • Scale: -
  • Frequency (Hz): 47...53
  • 13 láminas

INFORMATION

Description

  • Does not need an auxiliary power supply
  • DIN box with dimensions 96 and 144 mm
  • Class 1.5
  • Double scale

Applications

For the measurement and easy comparison of frequencies in alternating current circuits coming from generators or between the network and generator, when connected in parallel. The measurement is independent of the wave shape. For applications in severe environmental and physical conditions.

SPECIFICATIONS

Environmental characteristics
Protection class
Panel: IP 52 (Front), IP 00 (Terminals)
Storage temperature
-25…+40 °C
Working temperature
+10 … +30 °C
Standards
Certifications
UL
Electrical safety, Maximum height (m)
2000
Standards
BS 89, UNE-EN 60051, IEC 144, UL94, DIN 43780, IEC 51, UNE 21318
Voltage measurement circuit
Consumption
1 … 3,6 VA
Sampling frequency
47 … 53 Hz
Nominal voltage
230 V ~
Maximum permanent measurement voltage
1,2 Vn permanent rated voltage / 2 Vn during 5s
Electrical characteristics
Insulation voltage, circuit
2kV a 50 Hz < 1min entre mecanismo y caja
Mechanical characteristics
Weight (kg)
0,45
Measurement accuracy
Accuracy
0,5 % FE

DIMENSIÓN

VÍDEOS

DESCARGAS

Datasheet

ACCESORIOS