{"id":27238,"date":"2022-07-07T10:26:05","date_gmt":"2022-07-07T08:26:05","guid":{"rendered":"https:\/\/circutor.com\/sem-categoria\/se-dispara-con-frecuencia-el-diferencial-de-tu-instalacion-que-debes-saber-para-solucionarlo\/"},"modified":"2022-07-19T13:10:39","modified_gmt":"2022-07-19T11:10:39","slug":"com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema","status":"publish","type":"post","link":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/","title":{"rendered":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o? Siga estes passos para solucionar este problema"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Na CIRCUTOR deparamo-nos frequentemente com instala\u00e7\u00f5es que apresentam problemas de disparos nos diferenciais, o que leva a perturba\u00e7\u00f5es e paragens nos processos de produ\u00e7\u00e3o e que, em algumas ocasi\u00f5es, chegam a ser cr\u00edticos. Perante estas circunst\u00e2ncias, \u00e9 indispens\u00e1vel dispor de informa\u00e7\u00e3o b\u00e1sica da instala\u00e7\u00e3o para poder fazer uma an\u00e1lise completa das causas dos disparos. S\u00f3 assim \u00e9 poss\u00edvel encontrar a melhor solu\u00e7\u00e3o de uma forma r\u00e1pida, eficaz e, certamente, segura.<\/p>\n<p><strong>Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.<\/strong>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Em primeiro lugar, quando uma instala\u00e7\u00e3o apresenta disparos intempestivos de diferenciais \u00e9 imprescind\u00edvel que re\u00fana a seguinte informa\u00e7\u00e3o:[\/vc_column_text][vc_empty_space height=&#8221;12px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_message message_box_color=&#8221;grey&#8221; icon_fontawesome=&#8221;fas fa-clipboard&#8221;]<strong>Tipo de regime de neutro da instala\u00e7\u00e3o: TT, TN (TN-S ou TN-C) ou IT.<\/strong><\/p>\n<p>Esta informa\u00e7\u00e3o serve para verificar se \u00e9 oportuno usar dois diferenciais. Pode encontrar informa\u00e7\u00e3o adicional das carater\u00edsticas dos distintos regimes de neutro e as suas considera\u00e7\u00f5es em rela\u00e7\u00e3o \u00e0 prote\u00e7\u00e3o diferencial nestas liga\u00e7\u00f5es.[\/vc_message][vc_message icon_fontawesome=&#8221;fas fa-clipboard&#8221;]<strong>Outro dos pontos-chave \u00e9 conhecer o esquema da instala\u00e7\u00e3o: <\/strong>pode servir tanto um esquema trifilar como unifilar. Em todo o caso, devem indicar-se, pelo menos, estes dados:[\/vc_message][\/vc_column][\/vc_row][vc_row][vc_column][vc_single_image image=&#8221;26237&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;zoom&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_message icon_fontawesome=&#8221;fas fa-clipboard&#8221;]<strong>Disposi\u00e7\u00e3o dos interruptores diferenciais da instala\u00e7\u00e3o:<\/strong> ter\u00e1 de se indicar sempre a sensibilidade, tempo de atraso ajustado na prote\u00e7\u00e3o, tipo de diferencial (AC; A; F ou B), marca e modelo do diferencial (para conhecer melhor as suas presta\u00e7\u00f5es) e os diferenciais diretos ou os que t\u00eam um transformador externo associado. Uma m\u00e1 escolha do tipo diferencial pode estar a provocar disparos. Em muitas ocasi\u00f5es. os disparos podem de facto ser facilmente evitados utilizando diferenciais devidamente imunizados contra perturba\u00e7\u00f5es transit\u00f3rias ou harm\u00f3nicas.[\/vc_message][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_raw_html]JTNDaSUyMGNsYXNzJTNEJTIyaWNvLXNjYWRhLXNjcmVlbiUyMiUyMHN0eWxlJTNEJTIyZm9udC1zaXplJTNBMnJlbSUzQiUyMiUzRSUzQyUyRmklM0U=[\/vc_raw_html][vc_column_text]<\/p>\n<p class=\"p1\"><span class=\"s1\"><b>Margem de disparo entre 85% &#8211; 100% da sensibilidade.<\/b><\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_raw_html]JTNDaSUyMGNsYXNzJTNEJTIyaWNvLWJhcnMtY29uc3VtcHRpb24lMjIlMjBzdHlsZSUzRCUyMmZvbnQtc2l6ZSUzQTJyZW0lM0IlMjIlM0UlM0MlMkZpJTNF[\/vc_raw_html][vc_column_text]<\/p>\n<p class=\"p1\"><span class=\"s1\"><b>Resposta de frequ\u00eancia com filtragem de fuga de alta frequ\u00eancia.<\/b><\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_raw_html]JTNDaSUyMGNsYXNzJTNEJTIyaWNvLWVsZWN0cmljLXByb3RlY3Rpb24lMjIlMjBzdHlsZSUzRCUyMmZvbnQtc2l6ZSUzQTJyZW0lM0IlMjIlM0UlM0MlMkZpJTNF[\/vc_raw_html][vc_column_text]<\/p>\n<p class=\"p1\"><span class=\"s1\"><b>Mais imunidade a transistores de rede at\u00e9 3 kA para impulsos de 8\/20 \u03bcs<\/b><\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_message icon_fontawesome=&#8221;fas fa-clipboard&#8221;]<strong>O esquema unifilar:<\/strong> tamb\u00e9m dever\u00e1 indicar o tipo de cargas que existe na instala\u00e7\u00e3o, bem como a sua rela\u00e7\u00e3o de pot\u00eancia (kw) ou corrente (A). Isto \u00e9 de vital import\u00e2ncia, dado que um dos pontos cr\u00edticos na escolha do diferencial \u00e9 o transformador adequado para a corrente de carga associada. H\u00e1 que ter em conta que pontos de corrente superiores aos tolerados pelo transformador geram falsos disparos.[\/vc_message][vc_message icon_fontawesome=&#8221;fas fa-clipboard&#8221;]<strong>Poss\u00edveis problemas:<\/strong> h\u00e1 que assinalar de forma clara no esquema quais os diferenciais que apresentam problemas de disparos.[\/vc_message][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>Tamb\u00e9m pode ser bastante \u00fatil conhecer a casu\u00edstica quando se produz o disparo:<\/strong> \u00e9 completamente aleat\u00f3rio?, em que momento se produz?, a uma hora concreta do dia?, quando come\u00e7a um processo concreto? \u00c0s vezes, podemos relacionar o disparo com uma causa-efeito.<\/p>\n<p>Se o diferencial que dispara \u00e9 um sistema indireto (ou seja, rel\u00e9 + transformador) e as correntes come\u00e7am a alcan\u00e7ar certos valores (&gt;400A), \u00e9 bastante \u00fatil verificar como os cabos de pot\u00eancia est\u00e3o passados por dentro do transformador. Uma disposi\u00e7\u00e3o med\u00edocre, com os cabos pouco centrados ou embutidos devido \u00e0 escolha de um transformador demasiado pequeno, ou com cotovelos perto do centro do transformador, pode afetar de forma determinante a medida de corrente de fuga, originando estes disparos falsos.<\/p>\n<p>Por \u00faltimo, embora n\u00e3o menos importante, \u00e9 tamb\u00e9m \u00fatil conhecer o valor de fuga com que o diferencial dispara. Esta informa\u00e7\u00e3o s\u00f3 est\u00e1 dispon\u00edvel quando o diferencial disp\u00f5e de display ou comunica\u00e7\u00f5es, j\u00e1 que alguns dispositivos (como a fam\u00edlia RGU de CIRCUTOR) guardam o valor do \u00faltimo ciclo antes do disparo. Este valor pode dar-nos pistas muito importantes para descobrir a origem do problema.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_column_text]<\/p>\n<p style=\"text-align: center;\"><span style=\"color: #426da8;\"><strong>RGU-100B <\/strong>Rel\u00e9 de prote\u00e7\u00e3o e monitoriza\u00e7\u00e3o diferencial de tipo B<\/span><\/p>\n<p>[\/vc_column_text][vc_single_image image=&#8221;26051&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; img_link_target=&#8221;_blank&#8221; link=&#8221;https:\/\/circutor.com\/pt-pt\/produtos\/protecao-e-controlo\/protecao-diferencial\/protecao-diferencial-tipo-b\/product\/P11961.\/&#8221;][vc_column_text]<\/p>\n<p class=\"p1\" style=\"text-align: center;\">Visualiza\u00e7\u00e3o e monitoriza\u00e7\u00e3o em tempo real:<strong> Fuga em alternada + Fuga em cont\u00ednua= Fuga total<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;36px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]Sempre que poss\u00edvel, tamb\u00e9m ser\u00e1 \u00fatil tomar medidas com um analisador port\u00e1til dos par\u00e2metros el\u00e9tricos da instala\u00e7\u00e3o. Bem como medir a corrente de fuga naqueles circuitos que apresentem os problemas.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;15430&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; link=&#8221;https:\/\/circutor.com\/pt-pt\/produtos\/medicao-e-controlo\/analisadores-de-redes-portateis\/analisadores-de-red-portateis\/serie\/myebox\/&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<span style=\"color: #426da8;\"><strong>MYeBOX\u00a0 \u00a0<\/strong>Analisador de redes port\u00e1til trif\u00e1sico com registo de eventos de qualidade e transit\u00f3rios<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<strong>Seguir estes passos dar-lhe-\u00e1 a informa\u00e7\u00e3o necess\u00e1ria e pode ajudar a comprovar se a escolha das sensibilidades, os tempos de atraso e o tipo de diferencial s\u00e3o adequados para o tipo de carga que est\u00e3o a proteger.<\/strong> Tamb\u00e9m faz com que seja comprovar que a seletividade vertical cumpre as condi\u00e7\u00f5es amperim\u00e9tricas, cronom\u00e9tricas e de tipo que s\u00e3o necess\u00e1rias para evitar disparos em subquadros ou quadros gerais.<\/p>\n<p>A an\u00e1lise de toda esta informa\u00e7\u00e3o d\u00e1-lhe algumas luzes sobre o assunto e pode ajudar a encontrar a melhor solu\u00e7\u00e3o.<\/p>\n<p class=\"p1\"><span class=\"s1\">[vc_empty_space height=&#8221;20px&#8221;]<\/span><\/p>\n<p>[\/vc_column_text][vc_separator border_width=&#8221;3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_btn title=&#8221;Mais informa\u00e7\u00f5es sobre prote\u00e7\u00e3o diferencial&#8221; style=&#8221;custom&#8221; custom_background=&#8221;#e40040&#8243; custom_text=&#8221;#ffffff&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fcircutor.com%2Fpt-pt%2Fprodutos%2Fprotecao-e-controlo%2F|target:_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Na CIRCUTOR deparamo-nos frequentemente com instala\u00e7\u00f5es que apresentam problemas de disparos nos diferenciais, o que leva a perturba\u00e7\u00f5es e paragens nos processos de produ\u00e7\u00e3o e que, em algumas ocasi\u00f5es, chegam a ser cr\u00edticos. Perante estas circunst\u00e2ncias, \u00e9 indispens\u00e1vel dispor de informa\u00e7\u00e3o b\u00e1sica da instala\u00e7\u00e3o para poder fazer uma an\u00e1lise completa das causas dos disparos. S\u00f3 [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":26129,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3525],"tags":[3599,3649],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?<\/title>\n<meta name=\"description\" content=\"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?\" \/>\n<meta property=\"og:description\" content=\"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2022-07-07T08:26:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-19T11:10:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/iStock-942864154_cuadres_electrics.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Circutor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Circutor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\",\"url\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\",\"name\":\"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2022-07-07T08:26:05+00:00\",\"dateModified\":\"2022-07-19T11:10:39+00:00\",\"description\":\"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/pt-pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o? Siga estes passos para solucionar este problema\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\"},\"author\":{\"name\":\"Circutor\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/06cd1bedf12980260d76632f5805f930\"},\"headline\":\"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o? Siga estes passos para solucionar este problema\",\"datePublished\":\"2022-07-07T08:26:05+00:00\",\"dateModified\":\"2022-07-19T11:10:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/\"},\"wordCount\":1248,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"keywords\":[\"An\u00e1lise de instala\u00e7\u00f5es\",\"Prote\u00e7\u00e3o el\u00e9trica\u00a0\"],\"articleSection\":[\"Artigos\"],\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/06cd1bedf12980260d76632f5805f930\",\"name\":\"Circutor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"caption\":\"Circutor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?","description":"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/","og_locale":"pt_PT","og_type":"article","og_title":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?","og_description":"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.","og_url":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2022-07-07T08:26:05+00:00","article_modified_time":"2022-07-19T11:10:39+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/iStock-942864154_cuadres_electrics.jpg","type":"image\/jpeg"}],"author":"Circutor","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"Escrito por":"Circutor","Tempo estimado de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"pt-PT"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/","url":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/","name":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o?","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2022-07-07T08:26:05+00:00","dateModified":"2022-07-19T11:10:39+00:00","description":"Esperamos que o que iremos descrever em seguida lhe seja \u00fatil para p\u00f4r fim aos disparos nos diferenciais das suas instala\u00e7\u00f5es.","breadcrumb":{"@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/pt-pt\/"},{"@type":"ListItem","position":2,"name":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o? Siga estes passos para solucionar este problema"}]},{"@type":"Article","@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#article","isPartOf":{"@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/"},"author":{"name":"Circutor","@id":"https:\/\/circutor.com\/#\/schema\/person\/06cd1bedf12980260d76632f5805f930"},"headline":"Com frequ\u00eancia o dispara o diferencial da sua instala\u00e7\u00e3o? Siga estes passos para solucionar este problema","datePublished":"2022-07-07T08:26:05+00:00","dateModified":"2022-07-19T11:10:39+00:00","mainEntityOfPage":{"@id":"https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/"},"wordCount":1248,"commentCount":0,"publisher":{"@id":"https:\/\/circutor.com\/#organization"},"keywords":["An\u00e1lise de instala\u00e7\u00f5es","Prote\u00e7\u00e3o el\u00e9trica\u00a0"],"articleSection":["Artigos"],"inLanguage":"pt-PT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/circutor.com\/pt-pt\/artigos\/com-frequencia-o-dispara-o-diferencial-da-sua-instalacao-siga-estes-passos-para-solucionar-este-problema\/#respond"]}]},{"@type":"Person","@id":"https:\/\/circutor.com\/#\/schema\/person\/06cd1bedf12980260d76632f5805f930","name":"Circutor","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/circutor.com\/#\/schema\/person\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"Circutor"}}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/posts\/27238"}],"collection":[{"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/comments?post=27238"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/posts\/27238\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/media\/26129"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/media?parent=27238"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/categories?post=27238"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/circutor.com\/pt-pt\/wp-json\/wp\/v2\/tags?post=27238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}