{"id":10481,"date":"2014-10-23T08:00:00","date_gmt":"2014-10-23T08:00:00","guid":{"rendered":"https:\/\/circutorweb.atic.blue\/?p=154"},"modified":"2014-10-23T08:00:00","modified_gmt":"2014-10-23T08:00:00","slug":"reinventer-la-compensation-de-reactive","status":"publish","type":"post","link":"https:\/\/circutor.com\/fr\/uncategorized\/reinventer-la-compensation-de-reactive\/","title":{"rendered":"R\u00e9inventer la Compensation de R\u00e9active"},"content":{"rendered":"<p class=\"dark\">Un facteur important, qui normalement n&rsquo;est pas envisag\u00e9 \u00e0 l&rsquo;heure de compenser, est le <strong>propre d\u00e9s\u00e9quilibre des charges<\/strong>. L&#8217;emploi de syst\u00e8mes de compensation mesurant dans une seule phase et uniquement compens\u00e9s avec des condensateurs triphas\u00e9s, <strong>peut supposer une surcompensation du syst\u00e8me<\/strong>, en obtenant un <strong>r\u00e9sultat contraire \u00e0 celui souhait\u00e9<\/strong>, \u00e0 savoir am\u00e9liorer le facteur de puissance et les pertes dans les syst\u00e8mes de distribution.<\/p>\n<p class=\"dark\">Tout ce, ajout\u00e9 \u00e0 l&rsquo;extension des compteurs d&rsquo;\u00e9nergie \u00e9lectroniques (smart meters), capables d&rsquo;enregistrer sous une forme individuelle la consommation par phase, et aux nouvelles formes de p\u00e9nalisation qui visent les p\u00e9nalisations pour consommation par capacitive, nous a fait <strong>r\u00e9inventer une fois encore les syst\u00e8mes traditionnels de compensation d&rsquo;\u00e9nergie r\u00e9active<\/strong>.<\/p>\n<p class=\"dark\">CIRCUTOR pr\u00e9sente sa <strong>nouvelle gamme de batteries OPTIM HYB<\/strong>, capables de r\u00e9aliser la compensation de r\u00e9active en partant d&rsquo;une <strong>mesure r\u00e9elle triphas\u00e9e<\/strong> du syst\u00e8me (mesure des trois phases au lieu d&rsquo;une). Gr\u00e2ce \u00e0 la combinaison de la compensation avec des condensateurs <strong>monophas\u00e9s<\/strong> (F-N) <strong>avec des thyristors<\/strong>, et <strong>triphas\u00e9s<\/strong> (III) avec des contacteurs, nous pouvons r\u00e9aliser une compensation individualis\u00e9e, rapide et pr\u00e9cise pour chaque phase.<\/p>\n<p>{youtube}uEvvmqt-y7I{\/youtube}<\/p>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p>Voir le&nbsp;catalogue:&nbsp;<a style=\"background-color: #eeeeee;\" href=\"http:\/\/circutor.fr\/fr\/documentation\/compensation-de-l-energie-reactive-et-filtrage-d-harmoniques\/batteries-de-condensateurs-pour-basse-tension\/2526-optim-hyb-batteries-de-condensateurs-automatiques-avec-manoeuvre-hybride\">Batteries de condensateurs automatiques avec manoeuvre hybride OPTIM HYB<\/a><a href=\"http:\/\/circutor.fr\/fr\/documentation\/catalogues\/protection-et-controle\/protection-differentielle-industrielle\/1509-gamme-complete-d-equipements-de-protection-et-surveillance-differentielle-classe-b\"><br \/><\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p>Plus d&rsquo;information:&nbsp;<a href=\"http:\/\/circutor.fr\/fr\/produits\/nouveautes\/2521-batteries-de-condensateurs-automatiques-avec-manoeuvre-hybride-optim-hyb\">Batteries de condensateurs automatiques avec manoeuvre hybride OPTIM HYB<\/a><a href=\"https:\/\/circutor.com\/es\/documentacion-es\/articulos\/1226-las-3-reglas-esenciales-para-la-selectividad-en-protecciones-diferenciales\"><br \/><\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p>Fiche technique:&nbsp;<a href=\"http:\/\/circutor.fr\/fr\/produits\/compensation-de-l-energie-reactive-et-filtrage-d-harmoniques\/batteries-de-condensateurs-pour-basse-tension\/serie-optim-hyb-detail\">Batteries de condensateurs automatiques avec manoeuvre hybride<\/a>&nbsp;(fiche technique, manuel, catalogue, etc.)<\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p>Vous pouvez vous informer de nos nouveaut\u00e9s dans la <a href=\"http:\/\/circutor.fr\/fr\/enterprise\/nouveautes\/nouveautes\">section des nouvelles<\/a>.<br \/>Vous pouvez \u00e9galement suivre nos publications sur le <a href=\"https:\/\/twitter.com\/circutor\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Twitter<\/a>&nbsp;de CIRCUTOR et sur <a href=\"http:\/\/www.linkedin.com\/company\/circutor\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">LinkedIn<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Un facteur important, qui normalement n&rsquo;est pas envisag\u00e9 \u00e0 l&rsquo;heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges. L&#8217;emploi de syst\u00e8mes de compensation mesurant dans une seule phase et uniquement compens\u00e9s avec des condensateurs triphas\u00e9s, peut supposer une surcompensation du syst\u00e8me, en obtenant un r\u00e9sultat contraire \u00e0 celui souhait\u00e9, \u00e0 savoir am\u00e9liorer le facteur de [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[33],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR<\/title>\n<meta name=\"description\" content=\"Un facteur important, qui normalement n&#039;est pas envisag\u00e9 \u00e0 l&#039;heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR\" \/>\n<meta property=\"og:description\" content=\"Un facteur important, qui normalement n&#039;est pas envisag\u00e9 \u00e0 l&#039;heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2014-10-23T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1299\" \/>\n\t<meta property=\"og:image:height\" content=\"354\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\",\"url\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\",\"name\":\"R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2014-10-23T08:00:00+00:00\",\"dateModified\":\"2014-10-23T08:00:00+00:00\",\"description\":\"Un facteur important, qui normalement n'est pas envisag\u00e9 \u00e0 l'heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"R\u00e9inventer la Compensation de R\u00e9active\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\"},\"headline\":\"R\u00e9inventer la Compensation de R\u00e9active\",\"datePublished\":\"2014-10-23T08:00:00+00:00\",\"dateModified\":\"2014-10-23T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/\"},\"wordCount\":287,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"caption\":\"admin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR","description":"Un facteur important, qui normalement n'est pas envisag\u00e9 \u00e0 l'heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/","og_locale":"fr_FR","og_type":"article","og_title":"R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR","og_description":"Un facteur important, qui normalement n'est pas envisag\u00e9 \u00e0 l'heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.","og_url":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2014-10-23T08:00:00+00:00","og_image":[{"width":1299,"height":354,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"\u00c9crit par":"admin","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/","url":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/","name":"R\u00e9inventer la Compensation de R\u00e9active - CIRCUTOR","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2014-10-23T08:00:00+00:00","dateModified":"2014-10-23T08:00:00+00:00","description":"Un facteur important, qui normalement n'est pas envisag\u00e9 \u00e0 l'heure de compenser, est le propre d\u00e9s\u00e9quilibre des charges.","breadcrumb":{"@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/fr\/"},{"@type":"ListItem","position":2,"name":"R\u00e9inventer la Compensation de R\u00e9active"}]},{"@type":"Article","@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#article","isPartOf":{"@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/"},"author":{"name":"admin","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283"},"headline":"R\u00e9inventer la Compensation de R\u00e9active","datePublished":"2014-10-23T08:00:00+00:00","dateModified":"2014-10-23T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/"},"wordCount":287,"commentCount":0,"publisher":{"@id":"https:\/\/circutor.com\/#organization"},"articleSection":["Uncategorized"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/circutor.com\/fr\/non-classifiee\/reinventer-la-compensation-de-reactive\/#respond"]}]},{"@type":"Person","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283","name":"admin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/circutor.com\/#\/schema\/person\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"admin"}}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/posts\/10481"}],"collection":[{"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/comments?post=10481"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/posts\/10481\/revisions"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/media?parent=10481"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/categories?post=10481"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/circutor.com\/fr\/wp-json\/wp\/v2\/tags?post=10481"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}