{"id":10386,"date":"2019-04-29T06:29:00","date_gmt":"2019-04-29T06:29:00","guid":{"rendered":"https:\/\/circutorweb.atic.blue\/?p=768"},"modified":"2019-04-29T06:29:00","modified_gmt":"2019-04-29T06:29:00","slug":"recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems","status":"publish","type":"post","link":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/","title":{"rendered":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems"},"content":{"rendered":"<h4>Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly. We are talking about plants whose industrial processes are vital, the telecommunications industry, the food and pharmaceutical industries, among others.<\/h4>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<p><strong>Power supply continuity<\/strong> is closely related to devices offering electric protection, another fundamental aspect of any electrical installation <strong>Protection devices<\/strong> are responsible for supply outages in our own installation, which may affect several lines depending on which protection device is involved.<\/p>\n<p>Ideally, protection devices should trigger whenever there is a safety risk to those operating the installations or a risk of damaging machinery connected to the network. Having said this, protection devices not only trigger in the event of a real threat, but more often than not <strong>transient disturbances<\/strong> with no serious effect on the installation are responsible, and this type of scenario is precisely when protection and power supply continuity come into play.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<p>As a result of the growing demand for solutions that aim to guarantee power supply continuity, devices have been developed to keep installations permanently working without risking personal safety or damage to machinery. <strong>Protection devices with self-reclosing systems<\/strong> are responsible for <strong>restoring power<\/strong> when there are no longer any risks of doing so. Thanks to such devices, the inconvenience, unnecessary costs and time wasted (in addition to the inherent output losses due to power supply shutdown) in manually switching circuit breakers back on are avoided, especially when they are sometimes located far away, are inaccessible or simply difficult to reach.<\/p>\n<p>They have a wide range of applications since they are suitable for all isolated, mainly unsupervised installations, but where a good balance between safety and power supply continuity is of paramount importance.<\/p>\n<\/p><\/div><\/div><\/div>\n<h4>What are the causes of untimely circuit breaker tripping?<\/h4>\n<p>Reasons for untimely tripping vary widely. From the presence of harmonic currents in the network to the variable behaviour of loads in the installation, including environmental factors such as lightning during a thunderstorm. As will be seen below, any tripping of protection devices in autonomous installations that are far away or difficult to reach leads to substantial losses for many industries.<\/p>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<p><img loading=\"lazy\" class=\" size-full wp-image-762\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_torre_com.jpg\" alt=\"Telecommunications industry\" width=\"400\" height=\"266\" \/><\/p>\n<h5>Telecommunications industry<\/h5>\n<p><strong>Telecommunications centres<\/strong> for telephone, radio and television companies are often located on high ground like hills or mountainous areas to maximise the range they cover. When there are thunderstorms and lightning, any lightning that strikes areas adjacent to these centres could <strong>trip the earth leakage protection device<\/strong>. This event, though not causing any permanent system leakage, could render the telecommunications centre useless until a supervisor arrives to switch the circuit breaker back on. Bearing in mind the number of people affected by this type of situation, financial losses for telecommunications companies may reach tens of thousands of euros per minute.<\/p>\n<p>The inconvenience and costs involved in bringing a technician to the area just to find out that the installation has not been seriously damaged must also be added to this cost.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\"><img loading=\"lazy\" class=\" size-full wp-image-763\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_ciutat.jpg\" alt=\"Public lighting systems and traffic management\" width=\"400\" height=\"266\" \/> <\/p>\n<h5>Public lighting systems and traffic management<\/h5>\n<p>In large cities, order largely depends on how traffic is managed. Correct synchronisation of traffic lights and signalling systems such as luminous panels are crucial for smooth traffic flow in large cities. Anything affecting elements that control traffic would lead to chaos, causing accidents or the busiest areas to come to a complete standstill.<\/p>\n<p>Likewise, most public lighting systems operate independently and are difficult to monitor due to the presence of multiple lamp posts spread out everywhere. As in the case of traffic management, untimely tripping in this type of installation would affect a large number of people and constitute a serious road safety hazard.<\/p>\n<\/p><\/div><\/div><\/div>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<p><img loading=\"lazy\" class=\" size-full wp-image-764\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_aigua-gas.jpg\" alt=\"Water and gas distribution systems\" width=\"400\" height=\"266\" \/><\/p>\n<h5>Water and gas distribution systems<\/h5>\n<p>Some <strong>water and gas supply<\/strong> phases take place in areas that are difficult to reach, thereby making it very complicated to restore supply. Furthermore, the typically slow response time of large companies to restore services could lead to outages lasting even longer.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\"><img loading=\"lazy\" class=\" size-full wp-image-765\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_frigo.jpg\" alt=\"Food sector companies \" width=\"400\" height=\"266\" \/> <\/p>\n<h5>Food sector companies<\/h5>\n<p>Turning to other sectors such as food, we have an industry whose needs for <strong>continuous power supply are extremely demanding<\/strong>. Take the case of large supermarkets: this type of business cannot afford lengthy power cuts to lines where refrigerating chambers are connected, as this would adversely affect the state of the stored product and may even result in large quantities of goods being thrown away.<\/p>\n<\/p><\/div><\/div><\/div>\n<h4>So what can we do to protect our installation without affecting power supply continuity?<\/h4>\n<p><strong>Circutor<\/strong>&#8216;s solution to the above-mentioned problems lies in the use of the <strong>RECmax CVM<\/strong> circuit breaker with self-reclosing earth leakage protection and inbuilt measurement.<\/p>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Designed for power supply continuity<\/h5>\n<p>The <strong>RECmax CVM<\/strong> features an electric motor designed to operate the switch when reclosing. Reclosing options (sensitivity, delay, reclosure number, reclosure time intervals, reset times) are programmable and enable fully autonomous power recovery.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Protection continues to be a priority<\/h5>\n<p>The <strong>RECmax CVM<\/strong> includes an over-voltage and short-circuit protection device, and also offers earth leakage protection in the event of leakage in the installation. The device guarantees installation safety at all times.<\/p>\n<\/p><\/div><\/div><\/div>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>What does CVM stand for?<\/h5>\n<p>The <strong>RECmax CVM<\/strong> features inbuilt measurement for <strong>over 250 electrical parameters<\/strong>, thereby enabling a much greater control over the installation&#8217;s behaviour. The display shows the key variables in your installation, such as voltages, currents, powers, harmonic distortion, power factor&#8230; as well as important protection parameters: protection status, real-time leakage, total number of trips or number of trips per protection type. The device allows you to browse different menus using its keypad, which can also be used to configure various reclosing parameters: <strong>sensitivity, delay, reclosure number, reclosure time intervals, reset time<\/strong>.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\" style=\"text-align: center;\"><img loading=\"lazy\" class=\" size-full wp-image-766\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_grafic-en.jpg\" alt=\"RECmax CVM features inbuilt measurement for over 250 electrical parameters\" width=\"298\" height=\"266\" \/><\/div><\/div><\/div>\n<h4>Advantages of CIRCUTOR&#8217;s RECmax CVM<\/h4>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Save time, space and money<\/h5>\n<p>The <strong>RECmax CVM<\/strong>&#8216;s Plug&Play system minimises installation time to just a few minutes. Both the <strong>efficient MC measurement transformers<\/strong> and the <strong>WGC<\/strong> differential sensor are included in the kit, through which you simply need to feed the power cables, connect them to the device using the plug-in connection terminals, and the device is ready. The aforementioned wiring is all you need for the <strong>RECmax CVM<\/strong> to start operating, since it is self-powered through an internal connection to the circuit breaker.<\/p>\n<p>Taking up just 7.5 modules of space for the 4-pole model and 5.5 modules for the 2-pole model, the <strong>RECmax CVM<\/strong> is a compact device suitable for installation in switchboards with limited available space.<\/p>\n<p>The equivalent application with separate devices would require 3 more modules and cost 25% more.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\"><img loading=\"lazy\" class=\" alignleft size-full wp-image-767\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2019\/04\/FD_RECmaxCVM_espai.jpg\" alt=\"Save time, space and money\" style=\"margin: 10px; float: left;\" width=\"150\" height=\"266\" \/> <\/p>\n<h5>Ultra-immunised<\/h5>\n<p>The ultra-immunised system, present in other products in Circutor&#8217;s earth leakage protection range, offers the following advantages:<\/p>\n<ul>\n<li>The earth leakage device triggers when reaching 85% of the threshold leakage value, which is when there is a serious risk to the installation and its users.<\/li>\n<li>Immunity against high-frequency currents<\/li>\n<li>Immunity against transient network variations<\/li>\n<\/ul><\/div><\/div><\/div>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Installation control<\/h5>\n<p>Thanks to the RS-485 communications port, the <strong>RECmax CVM<\/strong> may be added to <strong>SCADA<\/strong> systems for remote device management, enabling in-depth analysis of device readings as well as remote configuration. The device features two configurable digital outputs, very useful for controlling alarms or other external systems.<\/p>\n<p>By monitoring the unit, the status of the protection device may also be easily checked at all times, enabling remote intervention.<\/p>\n<p>The backlight display, in keeping with other devices in our company range, allows protection device status to be instantly checked. In the event of tripping, the screen (normally green) changes to red in order to detect faults in the installation at a glance, displaying the value of the current that caused the system to trip.<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Versatility<\/h5>\n<p>The <strong>RECmax CVM<\/strong> comes in 2-pole or 4-pole versions for all types of installations. Furthermore, the product range includes the possibility to choose from a 6A to 63A current range and a C or D trip curve.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" src=\"https:\/\/circutor.com\/images\/stories\/virtuemart\/product\/FO_RECmaxCVM_250x250.jpg\" alt=\"RECmaxCVM\" width=\"150\" height=\"150\" \/><\/p>\n<\/p><\/div><\/div><\/div>\n<div style=\"font-size: 12px; font-weight: bold; background-color: #fafafa; padding: 10px; border-style: solid; border-width: 1px; border-color: #e8e8e8;\">The above makes the RECmax CVM a very versatile product, an ideal device for: <\/p>\n<ul>\n<li>SAVING: Maximises power supply continuity<\/li>\n<li>SAFETY: Guarantees user safety and protects the installation&#8217;s machinery.<\/li>\n<li>MONITORING: Offers energy saving potential by monitoring, as well as detecting weak points in the installation that require preventive action.<\/li>\n<\/ul><\/div>\n<h3><a href=\"https:\/\/circutor.com\/en\/products\/protection-and-control\/earth-leakage-and-circuit-breaker-protection-with-reclosing-system\/overcurrent-and-earth-leakage-protection-and-self-reclosing\/recmaxcvm-series-detail\" target=\"_blank\" rel=\"noopener noreferrer\"><img src=\"https:\/\/circutor.com\/images\/stories\/virtuemart\/product\/resized\/FO_RECmaxCVM_250x250_55x55.jpg\" alt=\"RECmaxCVM\" \/>More information: RECmaxCVM<\/a><\/h3>\n<p>&nbsp;<\/p>\n<hr \/>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>RECmaxCVM guarantess the electrical continuity from unwanted trippings<\/h5>\n<p>{youtube}RqiQzIAKK-Q{\/youtube}<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>Saves energy with RECmaxCVM<\/h5>\n<p>{youtube}mLlqRnN1xuA{\/youtube}<\/p>\n<\/p><\/div><\/div><\/div>\n<div class=\"features-container\">\n<div class=\"feature-warp\">\n<div class=\"feature\">\n<h5>RECmaxCVM Plug&Play system saves time and space<\/h5>\n<p>{youtube}mK9uDE39JrM{\/youtube}<\/p>\n<\/p><\/div><\/div>\n<div class=\"feature-warp\">\n<div class=\"feature\">&nbsp;<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly. We are talking about plants whose industrial processes are vital, the telecommunications industry, the food and pharmaceutical industries, among others. Power [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":762,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[33],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR<\/title>\n<meta name=\"description\" content=\"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR\" \/>\n<meta property=\"og:description\" content=\"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2019-04-29T06:29:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1299\" \/>\n\t<meta property=\"og:image:height\" content=\"354\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\",\"url\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\",\"name\":\"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2019-04-29T06:29:00+00:00\",\"dateModified\":\"2019-04-29T06:29:00+00:00\",\"description\":\"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\"},\"headline\":\"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems\",\"datePublished\":\"2019-04-29T06:29:00+00:00\",\"dateModified\":\"2019-04-29T06:29:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/\"},\"wordCount\":1390,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"caption\":\"admin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR","description":"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/","og_locale":"en_GB","og_type":"article","og_title":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR","og_description":"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.","og_url":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2019-04-29T06:29:00+00:00","og_image":[{"width":1299,"height":354,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"Written by":"admin","Estimated reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/","url":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/","name":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems - CIRCUTOR","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2019-04-29T06:29:00+00:00","dateModified":"2019-04-29T06:29:00+00:00","description":"Recent developments in electrical installations have given power supply continuity top priority among all users of the electrical network, especially in those industrial sectors where outages cause serious economic losses, either directly or indirectly.","breadcrumb":{"@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/en\/"},{"@type":"ListItem","position":2,"name":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems"}]},{"@type":"Article","@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#article","isPartOf":{"@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/"},"author":{"name":"admin","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283"},"headline":"RECmaxCVM. Protect, reclose and measure. Avoid indirect costs to your installations by using reclosing systems","datePublished":"2019-04-29T06:29:00+00:00","dateModified":"2019-04-29T06:29:00+00:00","mainEntityOfPage":{"@id":"https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/"},"wordCount":1390,"commentCount":0,"publisher":{"@id":"https:\/\/circutor.com\/#organization"},"articleSection":["Uncategorized"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/circutor.com\/en\/uncategorized\/recmaxcvm-protect-reclose-and-measure-avoid-indirect-costs-to-your-installations-by-using-reclosing-systems\/#respond"]}]},{"@type":"Person","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/circutor.com\/#\/schema\/person\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"admin"}}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts\/10386"}],"collection":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/comments?post=10386"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts\/10386\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/media?parent=10386"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/categories?post=10386"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/tags?post=10386"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}