{"id":10283,"date":"2015-03-20T07:00:00","date_gmt":"2015-03-20T07:00:00","guid":{"rendered":"https:\/\/circutorweb.atic.blue\/?p=310"},"modified":"2015-03-20T07:00:00","modified_gmt":"2015-03-20T07:00:00","slug":"efficient-management-of-telecommunications-systems","status":"publish","type":"post","link":"https:\/\/circutor.com\/en\/articulos\/efficient-management-of-telecommunications-systems\/","title":{"rendered":"Efficient management of telecommunications systems"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h4>Key aspects for telecommunications companies<\/h4>\n<p>Telecommunications companies need&nbsp;to adapt their traditional management&nbsp;systems to other more robust and&nbsp;efficient ones. Nowadays, on-site&nbsp;management in the different centres is&nbsp;no longer sufficient. Success lies in&nbsp;automating the different control systems&nbsp;to obtain high quality installations that&nbsp;are reliable and available.<\/p>\n<p>The most critical point to bear in mind in&nbsp;telecommunications installations is&nbsp;ensuring supply continuity, because any&nbsp;incident of this type leads to serious&nbsp;complaints from users, and also&nbsp;requires human presence to fix the&nbsp;problem. However, another important&nbsp;aspect is controlling energy in a way&nbsp;that managers can remotely monitor&nbsp;and control each station to take&nbsp;immediate actions.<\/p>\n<h4>4 key objectives<\/h4>\n<p>As a reference in the electrical energy&nbsp;efficiency sector, CIRCUTOR offers&nbsp;telecommunications service companies&nbsp;a wide range of devices for successfully&nbsp;achieving the efficient control of their&nbsp;installations, both remote stations and&nbsp;data processing centres.<\/p>\n<p>There are several objectives that have&nbsp;to be borne in mind to achieve this, for&nbsp;instance:<\/p>\n<ol>\n<li>\n<h5>Supply continuity<\/h5>\n<p>Guaranteeing supply continuity with&nbsp;protection and earth leakage&nbsp;self-reclosing systems.<\/li>\n<li>\n<h5>Energy efficiency&nbsp;management<\/h5>\n<p>Guaranteeing the installation&#8217;s energy&nbsp;efficiency (control and reduction of&nbsp;consumption).<\/li>\n<li>\n<h5>Alarm management<\/h5>\n<p>Efficiently managing alarms (intruder&nbsp;detection, beacons, unwanted tripping,&nbsp;etc.)<\/li>\n<li>\n<h5>Management system creation<\/h5>\n<p>Guaranteeing a robust global management&nbsp;system of the different centres&nbsp;(centralised control).<\/li>\n<\/ol>\n<h4>How to meet the 4 objectives<\/h4>\n<hr \/>\n<h5>1. Supply continuity&nbsp;<\/h5>\n<p>Ensuring supply continuity is the most&nbsp;critical aspect in these types of installations.&nbsp;Any electrical outage leads to&nbsp;enormous economic losses and also&nbsp;requires human intervention to find a&nbsp;solution to the problem.<\/p>\n<p>The solution for mitigating this problem&nbsp;is the installation of <strong>CIRCUTOR&#8217;s<\/strong> circuit&nbsp;breakers with ultra-immunised earth&nbsp;leakage protection together with&nbsp;automatic self-reclosing devices such&nbsp;<strong>RECmax<\/strong>.<\/p>\n<p>The installation of ultra-immunised&nbsp;earth leakage relays guarantees correct&nbsp;actuation of the protections, which&nbsp;avoids possible unwanted tripping&nbsp;caused by malfunctions. Furthermore,&nbsp;the existence of devices with DC&nbsp;supply, such as UPS&#8217;s, requires the&nbsp;installation of <strong>type B earth leakage&nbsp;relays<\/strong> to monitor and protect the&nbsp;installation. <strong>Type B<\/strong> devices ensure the&nbsp;correct operation when there is a&nbsp;leakage current because they are&nbsp;specially designed to actuate when&nbsp;there is any fault with DC and AC&nbsp;component.<br \/>In turn, the self-reclosing system&nbsp;ensures supply continuity during a&nbsp;temporary fault, without the need for&nbsp;external intervention.<\/p>\n<p>It should be pointed out that those&nbsp;devices must be equipped with communications&nbsp;capacity for carrying out&nbsp;actions via remote control, monitoring&nbsp;the status of the protections on real&nbsp;time and acting accordingly when&nbsp;necessary for maintenance or&nbsp;prevention.<\/p>\n<p>Installing control devices for the&nbsp;external beacons, such as <strong>TB-3<\/strong>, is&nbsp;recommended as an additional element.&nbsp;These are designed to activate a&nbsp;burnt-out light alarm and can be&nbsp;integrated in management and control&nbsp;system.<\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-285\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-continuidad-en.jpg\" alt=\"Article-telecom-continuidad-en\" width=\"684\" height=\"199\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"width: 50%;\" valign=\"top\">\n<p><strong>RECmax<\/strong><br \/><strong>Earth leakage circuit breaker&nbsp;with self-reclosing system and display (LCD)<\/strong><\/p>\n<p>The <strong>RECmax LPd<\/strong> connected to the <strong>WGC \/ WGS<\/strong> toroidal&nbsp;transformers ensure earth leakage and circuit breaker&nbsp;protection with self-reclosing after an earth leakage,&nbsp;overload or short-circuit trip.<br \/>It is a good solution for those infrastructures that are hard to&nbsp;control and monitor because of their location in the following&nbsp;control boards:<\/p>\n<ul>\n<li>Phone systems<\/li>\n<li>DTT systems<\/li>\n<li>IT systems, UPS<\/li>\n<\/ul>\n<p><img loading=\"lazy\" class=\" size-full wp-image-286\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-fig-recmax.jpg\" alt=\"RECmax. Earth leakage circuit breaker with self-reclosing system and display (LCD)\" width=\"282\" height=\"178\" \/><\/p>\n<\/td>\n<td style=\"width: 50%;\" valign=\"top\">\n<p><strong>Type B<\/strong><br \/><strong>Full range of Type B earth leakage protection&nbsp;and monitoring devices<\/strong><\/p>\n<p><strong>CIRCUTOR&#8217;s<\/strong> range of <strong>Type B<\/strong> earth leakage protection units covers all the protection levels in your installation.<\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-287\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-fig-clase-b-en.jpg\" alt=\"Type B. Full range of Type B earth leakage protection and monitoring devices\" width=\"339\" height=\"243\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h5>2.&nbsp;Energy efficiency management<\/h5>\n<p>Every system aimed at electrical energy&nbsp;efficiency has to be equipped with&nbsp;devices that can log the electrical&nbsp;magnitudes in order to determine where&nbsp;and how energy is consumed. An&nbsp;analysis is done after said data is&nbsp;gathered to detect inefficiencies and&nbsp;take very specific corrective actions to&nbsp;achieve a higher energy efficiency.<br \/>Using <strong>CVM<\/strong>, electrical power analyzers,&nbsp;makes possible logging, monitoring and&nbsp;the management of electrical consumption&nbsp;and magnitudes in different&nbsp;centres.<br \/>For correct management, the measurements&nbsp;must be segmented for measuring&nbsp;at the installation mains and directly&nbsp;on the loads or units.<\/p>\n<ul>\n<li>\n<p><span style=\"color: #cd0039;\"><strong>Mains monitoring<\/strong>&nbsp;<\/span><\/p>\n<\/li>\n<\/ul>\n<p><img loading=\"lazy\" class=\" alignright size-full wp-image-288\" style=\"float: right;\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-ahorro-en.jpg\" alt=\"Capacitor bank Optim P&P. Savings on the electricity bill as a result of power factor correction\" width=\"50%\" height=\"NaN\" \/><\/p>\n<p style=\"margin-left: 30px;\">Monitoring the consumption at the main&nbsp;will log how much energy the centre&nbsp;consumes and <strong>whether the contracted&nbsp;power with the utility is adjusted&nbsp;to real usage or not<\/strong>. Consequently,&nbsp;the possibility of reducing the contracted&nbsp;power is the first piece of data to be&nbsp;assessed.<\/p>\n<p style=\"margin-left: 30px;\">Another important advantage is that&nbsp;<strong>self-billing<\/strong> is possible because&nbsp;real-time energy data is always&nbsp;available, and so the manager can&nbsp;<strong>anticipate receipt of the official&nbsp;invoice<\/strong> of the utility. Thanks to this, the&nbsp;accounting department will be able to&nbsp;<strong>accurately estimate payments<\/strong>.&nbsp;<\/p>\n<p style=\"margin-left: 30px;\">The <strong>reactive energy penalties<\/strong> cannot&nbsp;be ignored, as they may notably&nbsp;increase the electricity bill. This is why&nbsp;analyzers are a basic element for&nbsp;detecting the <strong>need for a capacitor&nbsp;bank installation to avoid unexpected&nbsp;penalties<\/strong> in the monthly bill.<\/p>\n<p style=\"margin-left: 30px;\">Installing an <strong>Optim P&P (Plug&Play)&nbsp;series<\/strong> capacitor bank will avoid&nbsp;reactive energy penalties in the centre,&nbsp;which will lower the electricity bill.<\/p>\n<ul>\n<li><span style=\"color: #cd0039;\"><strong>Monitoring the units<br \/><\/strong><\/span><\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\">In general, it is possible to estimate&nbsp;100% of the total energy consumed in&nbsp;stations or data processing centres,&nbsp;60% of which would be electricity&nbsp;consumed by infrastructure and the&nbsp;remaining 40% by cooling.<\/p>\n<ul style=\"list-style-type: circle;\">\n<li style=\"margin-left: 30px;\"><span style=\"color: #3366ff;\"><strong>Cooling<\/strong><\/span><\/li>\n<\/ul>\n<p style=\"margin-left: 60px;\">This shows that controlling cooling has&nbsp;an extremely important effect on the&nbsp;electricity bill. Temperature and&nbsp;humidity sensors have to be installed&nbsp;for correct management of the air&nbsp;conditioning systems, so as to be able&nbsp;to activate the fan and air-conditioning&nbsp;system.<\/p>\n<p style=\"margin-left: 60px;\">The key is using the digital outputs of&nbsp;the <strong>CIRCUTOR<\/strong> electrical power&nbsp;analyzers <strong>CVM<\/strong> or <strong>EDS<\/strong> energy managers,&nbsp;depending on the environmental&nbsp;features, for activating\/deactivating the&nbsp;fans. When management with fans&nbsp;does not suffice, the air-conditioning&nbsp;systems must be activated until the&nbsp;programmed setpoint is reached. This&nbsp;efficient and rational use of cooling&nbsp;systems enables important savings in&nbsp;this environment which, as we mentioned,&nbsp;makes up 40% of the total.<\/p>\n<ul style=\"list-style-type: circle;\">\n<li style=\"margin-left: 30px;\"><span style=\"color: #3366ff;\"><strong>Lighting<\/strong><\/span><\/li>\n<\/ul>\n<p style=\"margin-left: 60px;\">A global vision of the system cannot&nbsp;overlook lighting consumption management.&nbsp;The analysis of these consumptions&nbsp;is important to be able to estimate&nbsp;future energy savings that could be&nbsp;achieved by changing over to more&nbsp;efficient lighting systems. Historical&nbsp;data can be used for comparing energy&nbsp;savings in each centre based on the&nbsp;type of lighting system installed.<\/p>\n<ul style=\"list-style-type: circle;\">\n<li style=\"margin-left: 30px;\"><span style=\"color: #3366ff;\"><strong>IT devices<\/strong><\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" class=\" alignright size-full wp-image-289\" style=\"float: right;\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-conduct-en.jpg\" alt=\"The European Commission also has a code of conduct for reducing the impact of data centres' growing energy consumption.\" width=\"156\" height=\"230\" \/><\/p>\n<p style=\"margin-left: 60px;\">We can calculate the energy efficiency&nbsp;of any production system by comparing&nbsp;the useful energy with the total energy&nbsp;needed by the system. With this&nbsp;information and knowing where the&nbsp;inefficiencies are, we can achieve&nbsp;substantial savings and more environmentally-friendly operations.<\/p>\n<p style=\"margin-left: 60px;\">The energy factor is so critical in data&nbsp;processing centres that it has its own&nbsp;indicator: the <strong>Power Usage Effectiveness&nbsp;(PUE)<\/strong> defined by the Standard&nbsp;issued by <strong>The Green Grid<\/strong>, a global&nbsp;environmental agency comprised of&nbsp;over 175 internationally renowned&nbsp;companies.<\/p>\n<p style=\"margin-left: 60px;\">The <strong>European Commission<\/strong> also has&nbsp;a code of conduct for reducing the&nbsp;impact of data centres&#8217; growing energy&nbsp;consumption.<\/p>\n<p style=\"margin-left: 60px;\">The Commission has established the&nbsp;specific formula for calculating the PUE:<\/p>\n<p style=\"margin-left: 60px;\"><img loading=\"lazy\" class=\" size-full wp-image-290\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-pue-en.jpg\" alt=\"PUE = Total energy supplied \/ Energy for IT equipment\" width=\"204\" height=\"45\" \/><\/p>\n<p style=\"margin-left: 60px;\">Moreover, the Environmental Protection&nbsp;Agency of the United States (EPA)&nbsp;provides the following <strong>PUE values as a&nbsp;reference<\/strong>:<\/p>\n<p><img loading=\"lazy\" class=\" alignright size-full wp-image-291\" style=\"float: right;\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-google-en.jpg\" alt=\"Companies like Google have gotten the average PUE of their DPCs down to 1.22, and sometimes as low as 1.15.\" width=\"207\" height=\"138\" \/><\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>History log 2.0<\/li>\n<li>Current trend 1.9<\/li>\n<li>Optimised operations 1.7<\/li>\n<li>Best practices 1.3<\/li>\n<li>State-of-the-art 1.2<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\">Therefore, one of the keys to success in&nbsp;an energy improvement project lies in&nbsp;measuring the consumption of each&nbsp;device (air conditioning, communication&nbsp;units, UPS power supply, lighting,&nbsp;temperature, etc.) with electrical power&nbsp;analyzers <strong>CVM<\/strong>, in order to take&nbsp;appropriate action and achieve a higher&nbsp;performance.<\/p>\n<hr \/>\n<h5>3. Alarm management<\/h5>\n<p>Any time there is an alarm in a centre or&nbsp;station, it may involve the intervention&nbsp;by maintenance staff. There has to be a&nbsp;fast, safe and effective alarm system to&nbsp;be able to react on time and minimise&nbsp;operating costs. Telecommunications&nbsp;companies usually have their own alarm&nbsp;systems that send alerts via <strong>SNMP<\/strong>&nbsp;messages (Simple Network Management&nbsp;Protocol), which means that any&nbsp;system management has to be able to&nbsp;send different programmed alarms&nbsp;directly to the server.<\/p>\n<p>The energy data server <strong>EDS<\/strong>, responsible&nbsp;of managing the devices installed in&nbsp;the centre, will automatically send any&nbsp;alarm to the telecom SNMP main&nbsp;server. So immediately, the device will&nbsp;perform the appropriate action to&nbsp;mitigate the impact, whether acting&nbsp;directly or via remote management.<\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-292\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-solucion-scada-en.jpg\" alt=\"CIRCUTOR's solution with SCADA system\" width=\"436\" height=\"638\" \/><\/p>\n<hr \/>\n<h5>4. Management system creation<\/h5>\n<p>Once the devices necessary for locally&nbsp;controlling the centre or station have&nbsp;been determined, the global management&nbsp;infrastructure must be designed.&nbsp;The infrastructure must have the&nbsp;capacity to interact with each centre&nbsp;and, in turn, automatically report the&nbsp;stored information to provide a global&nbsp;view of the system.<\/p>\n<p>The information has to cascade from&nbsp;the source down to the control centre&nbsp;following a redundant data structure.<\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-293\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-sist-gestion-en.jpg\" alt=\"The installation's architecture would be designed in three blocks\" width=\"721\" height=\"886\" \/><\/p>\n<p><strong>The installation&#8217;s architecture would&nbsp;be designed in three blocks:<\/strong><\/p>\n<ul>\n<li><span style=\"color: #cd0039;\"><strong>Local management<\/strong><\/span><\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\">As explained in the previous points,&nbsp;different types of devices need to be&nbsp;chosen in order to achieve higher&nbsp;effectiveness in the electric energy&nbsp;management environment. Once the&nbsp;units have been chosen, they have to&nbsp;be connected to an energy manager&nbsp;equipped with communications and a&nbsp;database, such as the <strong>CIRCUTOR&nbsp;<\/strong>Efficiency data server (<strong>EDS<\/strong>).<\/p>\n<p style=\"margin-left: 30px;\">The <strong>EDS<\/strong> device uses Scada software&nbsp;for monitoring and storing in real time&nbsp;the different devices variables, and for&nbsp;the management of inputs\/outputs for&nbsp;controlling the station. It also uses&nbsp;Ethernet or 3G communications&nbsp;(depending on the model) for connecting&nbsp;to an intermediate management&nbsp;system.&nbsp;<\/p>\n<p style=\"margin-left: 30px;\">It should be noted that the <strong>EDS<\/strong> has the&nbsp;capacity to manage any alarm that&nbsp;appears in the centre, sending messages&nbsp;via SNMP to the telecommunications&nbsp;company&#8217;s central control server.<\/p>\n<p style=\"margin-left: 30px;\"><img loading=\"lazy\" class=\" size-full wp-image-294\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-gestion-local-en.jpg\" alt=\"Local management system\" width=\"668\" height=\"726\" \/><\/p>\n<ul>\n<li><strong><span style=\"color: #cd0039;\">Intermediate management<\/span><\/strong><\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\">Data transmission and treatment is one&nbsp;of the most important aspects that need&nbsp;to be defined. For the system to work&nbsp;properly, each centre or station has to&nbsp;be able to connect to a higher system&nbsp;with the capacity to centralise the&nbsp;control of the different centres. This&nbsp;system automatically requests all the&nbsp;data stored in the <strong>EDS<\/strong> managers, and&nbsp;also displays\/manages the status of&nbsp;each device.<\/p>\n<p style=\"margin-left: 30px;\">To do so, each local centre sends data&nbsp;to an intermediate server with <strong>PowerStudio Scada<\/strong> energy analysis software&nbsp;installed for centralising the control of&nbsp;each associated local centre.<\/p>\n<p style=\"margin-left: 30px;\">The <strong>PowerStudio Scada<\/strong> platform&nbsp;receives and stores all the regional&nbsp;information and subsequently sends it&nbsp;to the management system in the&nbsp;control centre. Therefore, a large&nbsp;amount of information is sectored&nbsp;without saturating the central server,&nbsp;which makes subsequent management&nbsp;more efficient whilst ensuring data&nbsp;redundancy, as the data is stored in the&nbsp;<strong>EDS<\/strong> manager and the <strong>PowerStudio&nbsp;Scada<\/strong> system.<\/p>\n<p style=\"margin-left: 30px;\">The associated devices in each centre&nbsp;or station can be remotely configured,&nbsp;controlled and monitored using the&nbsp;Scada application.<\/p>\n<p style=\"margin-left: 30px;\"><img loading=\"lazy\" class=\" size-full wp-image-295\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-gestion-intermedia-en.jpg\" alt=\"Intermediate management system\" width=\"477\" height=\"373\" \/><\/p>\n<ul>\n<li><strong><span style=\"color: #cd0039;\">Management Control Centre<\/span><\/strong><\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\">Managing the entire communications&nbsp;infrastructure must be handled from a&nbsp;central server to obtain a global vision&nbsp;of the installations.&nbsp;<\/p>\n<p style=\"margin-left: 30px;\">This requires installing a server that&nbsp;uses the <strong>PowerStudio Scada Deluxe<\/strong>&nbsp;platform. This global platform will add&nbsp;the different <strong>PowerStudio Scada<\/strong>&nbsp;installed in intermediate management&nbsp;sites so that it can feed from their&nbsp;databases and centralise the management&nbsp;of the entire infrastructure.<\/p>\n<p style=\"margin-left: 30px;\">In other words, the central application&nbsp;will be able to see the different intermediate&nbsp;servers, which in turn will allow&nbsp;the display and control of the local&nbsp;system controlled by different <strong>EDS<\/strong>&#8216; with&nbsp;their own management and control&nbsp;devices.<\/p>\n<p style=\"margin-left: 30px;\">After the central platform has been set&nbsp;up, data will be saved automatically in&nbsp;its server, and the entire database can&nbsp;be transmitted to other systems that are&nbsp;already installed. The application&nbsp;enables sending data directly from&nbsp;SQL, web service, XML (using a&nbsp;conversion module for this format).<\/p>\n<p style=\"margin-left: 30px;\">As mentioned above, the <strong>EDS<\/strong> units will&nbsp;also be able send alarms directly to the&nbsp;telecommunication company&#8217;s central&nbsp;alarm server via SNMP, perfectly&nbsp;integrating these devices in the existing&nbsp;infrastructure.<\/p>\n<p style=\"margin-left: 30px;\"><img loading=\"lazy\" class=\" size-full wp-image-296\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-gestion-control-en.jpg\" alt=\"Control centre architecture\" width=\"485\" height=\"439\" \/><\/p>\n<hr \/>\n<p><img loading=\"lazy\" class=\" size-full wp-image-297\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-powerstudio.jpg\" alt=\"PowerStudio Scada is the energy management software from CIRCUTOR\" width=\"237\" height=\"175\" \/><strong>PowerStudio Scada is the&nbsp;energy management&nbsp;software from CIRCUTOR<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"width: 50%;\" valign=\"top\">\n<p><strong>PowerStudio Scada&nbsp;For the INTERMEDIATE CENTRES&nbsp;control<\/strong><\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-298\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-pss.jpg\" alt=\"PowerStudio Scada\" width=\"232\" height=\"64\" \/><\/p>\n<ul>\n<li>Real-time display of variables<\/li>\n<li>Creation of databases<\/li>\n<li>Graphical representation<\/li>\n<li>Representation with data tables<\/li>\n<li>Creation of SCADA screens<\/li>\n<li>Creation of personalised reports<\/li>\n<li>Sending and reporting alarms (incidents)<\/li>\n<li>XML server<\/li>\n<li>Exporting data (.txt, and .cvs)<\/li>\n<\/ul>\n<hr \/>\n<p><strong>Application examples of the Scada PowerStudio\/Deluxe software<\/strong><\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-299\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-ejemplos-pss.jpg\" alt=\"Application examples of the Scada PowerStudio\/Deluxe software\" width=\"251\" height=\"326\" \/><\/p>\n<\/td>\n<td style=\"width: 50%;\" valign=\"top\">\n<p><strong>PowerStudio Scada DELUXE&nbsp;for the management from the main&nbsp;CONTROL CENTRE<\/strong><\/p>\n<p><img loading=\"lazy\" class=\" size-full wp-image-300\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-pss-luxe.jpg\" alt=\"PowerStudio Scada DELUXE\" width=\"305\" height=\"64\" \/><\/p>\n<p><strong>Power Studio Scada Deluxe +<\/strong> :<\/p>\n<ul>\n<li>Modbus generic driver (can be used to add any&nbsp;unit in the market with the Modbus protocol)<\/li>\n<li>OPC Client (Serves data to OPC systems)<\/li>\n<li>Multipoint PSS (Adds other PSS to a single&nbsp;control and management system)<\/li>\n<\/ul>\n<p style=\"margin-left: 30px;\"><img loading=\"lazy\" class=\" size-full wp-image-301\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-sql.jpg\" alt=\"SQL DATA EXPORT\" width=\"210\" height=\"68\" \/><\/p>\n<ul>\n<li>Converts the database to SQL and automatically<br \/>exports it to third-party systems<\/li>\n<\/ul>\n<hr \/>\n<p><img loading=\"lazy\" class=\" size-full wp-image-302\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-ejemplo-pue-en.jpg\" alt=\"WEEKLY PUE CALCULATION REPORT\" width=\"301\" height=\"352\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Example of the system&#8217;s global architecture<\/strong><\/p>\n<p><strong><span style=\"color: #3366ff;\">1. Local management<\/span><\/strong><br \/>EDS + control and management&nbsp;devices.<\/p>\n<p><strong><span style=\"color: #3366ff;\">2. Intermediate management<\/span><\/strong><br \/>Servers with <strong>PowerStudio Scada<\/strong> software for data management and controlling level \u008c<strong>(1)<\/strong>&nbsp;local installations&nbsp;<strong>\u008c<\/strong><\/p>\n<p><strong><span style=\"color: #3366ff;\">3. Management from the Control Centre<\/span><\/strong><br \/>Central server with&nbsp;<strong>PowerStudio&nbsp;Scada Deluxe<\/strong>&nbsp;for controlling intermediate level management <strong>(2)<\/strong> and level local management systems <strong>(1)<\/strong>.<br \/>Database management system for SQL, XML or WEB.<br \/>System for the management of SNMP alarms coming from <strong>(1)<\/strong> <strong>EDS<\/strong> devices.<\/p>\n<p><strong><img loading=\"lazy\" class=\" size-full wp-image-303\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/Article-telecom-ejemplo-arquitectura.jpg\" alt=\"Example of the system's global architecture\" width=\"638\" height=\"585\" \/><\/strong><\/p>\n<h4>Conclusions<\/h4>\n<p>As a company specialised in the energy&nbsp;efficiency sector, <strong>CIRCUTOR<\/strong> provides&nbsp;telecommunications companies the&nbsp;architecture they need for the management&nbsp;and control of all their centres or&nbsp;stations, and offers a large portfolio of&nbsp;devices, ALL of them dedicated to&nbsp;improving energy efficiency.<\/p>\n<p>Summarizing, with the installation of the&nbsp;proposed system, telecommunications&nbsp;companies will be able to improve the&nbsp;following areas:<\/p>\n<ul>\n<li>Security in supply continuity.<\/li>\n<li>Correct management and reduced&nbsp;consumption of cooling&nbsp;systems.<\/li>\n<li>Reduced electrical costs through&nbsp;measurements and preventive&nbsp;actions of the different loads.<\/li>\n<li>Reduced electricity costs&nbsp;through power factor correction.<\/li>\n<li>Improved power usage effectiveness&nbsp;(PUE) indicator, adapted to&nbsp;the levels recommended by the&nbsp;European Commission.<\/li>\n<li>Critical alarm control.<\/li>\n<li>Self-billing to be able to anticipate&nbsp;receipt of the utility bill\u0084\u0084<\/li>\n<li>Global and centralised management&nbsp;of the communication&nbsp;infrastructures (remote stations&nbsp;or data processing centres).<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p>Click here to download this article in <img loading=\"lazy\" class=\" size-full wp-image-37\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/04\/pdf.gif\" alt=\"pdf\" width=\"16\" height=\"16\" \/>&nbsp;PDF format<span style=\"background-color: #eeeeee;\">:&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_SP.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-5\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/01\/es.gif\" alt=\"es\" width=\"18\" height=\"12\" \/><\/a><span style=\"background-color: #eeeeee;\">&nbsp;&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_EN.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-7\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/01\/en.gif\" alt=\"en\" width=\"18\" height=\"12\" \/><\/a><span style=\"background-color: #eeeeee;\">&nbsp;&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_DE.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-9\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/01\/de.gif\" alt=\"de\" width=\"18\" height=\"12\" \/><\/a><span style=\"background-color: #eeeeee;\">&nbsp;&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_FR.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-11\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/01\/fr.gif\" alt=\"fr\" width=\"18\" height=\"12\" \/><\/a><span style=\"background-color: #eeeeee;\">&nbsp;&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_PL.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-186\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/07\/pl.gif\" alt=\"pl\" width=\"18\" height=\"12\" \/><\/a><span style=\"background-color: #eeeeee;\">&nbsp;&nbsp;<\/span><a style=\"background-color: #eeeeee;\" href=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2015\/03\/CIR201501_Telecom_PT.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" class=\" size-full wp-image-184\" src=\"https:\/\/circutorweb.atic.blue\/wp-content\/uploads\/2014\/07\/pt.gif\" alt=\"pt\" width=\"18\" height=\"12\" \/><\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p>More information about <a href=\"https:\/\/circutor.com\/en\/products\/protection-and-control\/earth-leakage-and-circuit-breaker-protection-with-reclosing-system\/earth-leakage-protection-and-self-reclosing\">Earth leakage protection and self-reclosing<\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p><span style=\"background-color: #eeeeee;\">More information about&nbsp;<\/span><a href=\"https:\/\/circutor.com\/en\/products\/protection-and-control\/earth-leakage-and-circuit-breaker-protection-with-reclosing-system\/overcurrent-and-earth-leakage-protection-and-self-reclosing\">Overcurrent and earth leakage protection and self-reclosing<\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 100%; background-color: #eeeeee;\">\n<tbody>\n<tr>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 250px;\" colspan=\"7\" valign=\"top\">\n<p><span style=\"background-color: #eeeeee;\">More information about&nbsp;<\/span><a href=\"https:\/\/circutor.com\/en\/products\/protection-and-control\/earth-leakage-and-circuit-breaker-protection-with-reclosing-system\/overcurrent-protection-and-self-reclosing\">Overcurrent protection and self-reclosing<\/a><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p>You can read our news in the&nbsp;<a href=\"https:\/\/circutor.com\/en\/company\/news\/news\">news section<\/a>.<br \/>You can also follow our publications on CIRCUTOR&#8217;s&nbsp;<a href=\"https:\/\/twitter.com\/circutor\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">Twitter account<\/a>, and on&nbsp;<a href=\"http:\/\/www.linkedin.com\/company\/circutor\" rel=\"nofollow noopener noreferrer\" target=\"_blank\">LinkedIn<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Key aspects for telecommunications companies Telecommunications companies need&nbsp;to adapt their traditional management&nbsp;systems to other more robust and&nbsp;efficient ones. Nowadays, on-site&nbsp;management in the different centres is&nbsp;no longer sufficient. Success lies in&nbsp;automating the different control systems&nbsp;to obtain high quality installations that&nbsp;are reliable and available. The most critical point to bear in mind in&nbsp;telecommunications installations is&nbsp;ensuring supply [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":285,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1138],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Efficient management of telecommunications systems - CIRCUTOR<\/title>\n<meta name=\"description\" content=\"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Efficient management of telecommunications systems - CIRCUTOR\" \/>\n<meta property=\"og:description\" content=\"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2015-03-20T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1299\" \/>\n\t<meta property=\"og:image:height\" content=\"354\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\",\"url\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\",\"name\":\"Efficient management of telecommunications systems - CIRCUTOR\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2015-03-20T07:00:00+00:00\",\"dateModified\":\"2015-03-20T07:00:00+00:00\",\"description\":\"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Efficient management of telecommunications systems\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\"},\"headline\":\"Efficient management of telecommunications systems\",\"datePublished\":\"2015-03-20T07:00:00+00:00\",\"dateModified\":\"2015-03-20T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/\"},\"wordCount\":2587,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"articleSection\":[\"Art\u00edculos\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"caption\":\"admin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Efficient management of telecommunications systems - CIRCUTOR","description":"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/","og_locale":"en_GB","og_type":"article","og_title":"Efficient management of telecommunications systems - CIRCUTOR","og_description":"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.","og_url":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2015-03-20T07:00:00+00:00","og_image":[{"width":1299,"height":354,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"Written by":"admin","Estimated reading time":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/","url":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/","name":"Efficient management of telecommunications systems - CIRCUTOR","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2015-03-20T07:00:00+00:00","dateModified":"2015-03-20T07:00:00+00:00","description":"Telecommunications companies need to adapt their traditional management systems to other more robust and efficient ones. Nowadays, on-site management in the different centres is no longer sufficient. Success lies in automating the different control systems to obtain high quality installations that are reliable and available.","breadcrumb":{"@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/en\/"},{"@type":"ListItem","position":2,"name":"Efficient management of telecommunications systems"}]},{"@type":"Article","@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#article","isPartOf":{"@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/"},"author":{"name":"admin","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283"},"headline":"Efficient management of telecommunications systems","datePublished":"2015-03-20T07:00:00+00:00","dateModified":"2015-03-20T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/"},"wordCount":2587,"commentCount":0,"publisher":{"@id":"https:\/\/circutor.com\/#organization"},"articleSection":["Art\u00edculos"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/circutor.com\/en\/articles\/efficient-management-of-telecommunications-systems\/#respond"]}]},{"@type":"Person","@id":"https:\/\/circutor.com\/#\/schema\/person\/17d169bdccd6e2367b1ce7182dd31283","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/circutor.com\/#\/schema\/person\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"admin"}}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts\/10283"}],"collection":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/comments?post=10283"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/posts\/10283\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/media?parent=10283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/categories?post=10283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/circutor.com\/en\/wp-json\/wp\/v2\/tags?post=10283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}