Resistance transducer

CR2 Out 2

CR2 Out 2, Transducer Ohm

Code: M25642.CONSULTAR DISPONIBILIDAD

  • Output type: 2
  • Analog output: 4…20mA
  • Measure: 1 … 200 kΩ

INFORMATION

Description

CR2 transducers, measure a circuit resistance. The analog output signal is directly proportional to the measurement resistance.
The input circuit is protected against 250V RMS accidental voltage.

SPECIFICATIONS

AC power supply, insulation
Pulse test (kV)
3 kV (1,2/50µs)
Test voltage (kV)
2 kV RMS 50 Hz 1min
AC power supply
Consumption
2,5 VA
Frequency
40…90 Hz
Nominal voltage
24/115/230/400 Vca (-15…+20%)
DC power supply, insulation
Pulse test (kV)
3 kV (1,2/50µs)
Test voltage (kV)
2 kV RMS 50Hz 1 min
DC power supply
Consumption
2,5 VA
Nominal voltage
9-18 / 18-36 Vdc 36-72 / 90-140 Vdc
Mechanical characteristics
Size (mm) width x height x depth
40 x 72 x 110 (mm)
Weight (kg)
0,31
Environmental characteristics
Protection class
IP 20 (Terminals) IP 40 (case)
Storage temperature
-40….+70 °C
Working temperature
-10…+60 °C
Current measurement circuit
Phase current measurement
20 … 200 Ω / 2 … 20 kΩ
Standards
Electrical safety, Maximum height (m)
2000
Standards
IEC 529, IEC 688, IEC 801, EN 50081-2, EN 50082-2, IEC 1010
Analogue inputs
Load impedance in current
< 500 Ω
Ripple (effective RMS value)
< 0,5 %
Load impedance in voltage
> 500 Ω
Response time
< 300 ms (0…99 % Vn)
Analogue outputs
Current mode, nominal range
0…10, 20 mAac
Displaced output
0,2…2 V / 2…10 V / 4…20 mA
Voltage mode: nominal output range
0…5, 10 Vac
Measurement accuracy
Phase current measurement
0,2 % FS

DIMENSIÓN

VÍDEOS

DESCARGAS

User's manual
Dimensions
Datasheet

ACCESORIOS

TAMBIÉN TE PUEDE INTERESAR