{"id":37893,"date":"2023-05-17T10:08:15","date_gmt":"2023-05-17T08:08:15","guid":{"rendered":"https:\/\/circutor.com\/?p=37893"},"modified":"2023-05-29T16:37:48","modified_gmt":"2023-05-29T14:37:48","slug":"les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2","status":"publish","type":"post","link":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/","title":{"rendered":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#8217;energia reactiva"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]El desenvolupament r\u00e0pid dels components principals dels sistemes fotovoltaics d&#8217;autoconsum cap a equips m\u00e9s eficients i menys costosos (tant pel que fa a les plaques de generaci\u00f3 fotovoltaica com als inversors per a la conversi\u00f3 CC\/CA) i la modificaci\u00f3 raonable i esperada de la regulaci\u00f3 nacional (que ha flexibilitzat i simplificat de manera significativa els tr\u00e0mits i les exig\u00e8ncies per a l&#8217;autogeneraci\u00f3 fotovoltaica) estan causant un increment notable i imparable de la implementaci\u00f3 de sistemes d&#8217;autoconsum.\u00a0I aix\u00f2 succeeix no nom\u00e9s en l&#8217;\u00e0mbit dom\u00e8stic, sin\u00f3 tamb\u00e9 en grans consumidors energ\u00e8tics a escala industrial i de serveis.[\/vc_column_text][vc_video link=&#8221;https:\/\/youtu.be\/5kM7viDvlNs&#8221; css=&#8221;.vc_custom_1685371003035{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text css=&#8221;.vc_custom_1684752673207{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;]Els beneficis d&#8217;aquest augment de l&#8217;autoconsum en instal\u00b7lacions de certa pot\u00e8ncia s\u00f3n innegables, tant per aconseguir els objectius fixats de reducci\u00f3 d&#8217;emissions de CO2 com per refor\u00e7ar la generaci\u00f3 distribu\u00efda.\u00a0D\u2019aquesta manera s&#8217;augmenta l&#8217;efici\u00e8ncia global de la xarxa de transmissi\u00f3 i distribuci\u00f3 de l&#8217;energia.\u00a0Correlativament, es redueixen les despeses energ\u00e8tiques i s\u2019incrementa la productivitat de les activitats.[\/vc_column_text][vc_column_text]No obstant aix\u00f2, des del punt de vista dels sistemes de compensaci\u00f3 de reactiva que puguin estar instal\u00b7lats, o b\u00e9 que s\u2019hagin d\u2019instal\u00b7lar, \u00e9s important tenir en compte una s\u00e8rie de consideracions que poden provocar el seu mal funcionament, cosa que fins i tot pot derivar en penalitzacions per exc\u00e9s de consum de reactiva que, fins a la implementaci\u00f3 del sistema d&#8217;autoconsum, no s&#8217;estaven produint.<\/p>\n<p>La instal\u00b7laci\u00f3 d&#8217;un sistema de generaci\u00f3 el\u00e8ctrica fotovoltaica per a autoconsum pot generar el mal funcionament dels equips de compensaci\u00f3 de reactiva existents. \u00c9s essencial con\u00e8ixer aquestes conseq\u00fc\u00e8ncies per evitar penalitzacions inesperades.[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1684752696239{margin-top: 40px !important;margin-bottom: 20px !important;}&#8221;]Problem\u00e0tica principal que planteja la compensaci\u00f3 de reactiva en instal\u00b7lacions on s&#8217;ha incorporat un sistema d&#8217;autoconsum[\/vc_column_text][vc_single_image image=&#8221;37435&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1683700448425{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]La pr\u00e0ctica totalitat dels problemes que poden sorgir tenen el seu origen en un concepte b\u00e0sic. Quan s\u2019instal\u00b7la un sistema d&#8217;autoconsum, redu\u00efm, en funci\u00f3 de la pot\u00e8ncia injectada per aquest sistema en cada moment, el consum d&#8217;energia activa (kW.h) de la xarxa (el consum registrat pel comptador de la companyia el\u00e8ctrica) pel que fa al consum que hi hauria en les mateixes condicions de c\u00e0rrega sense la generaci\u00f3 fotovoltaica.<\/p>\n<p>En funci\u00f3 del percentatge de generaci\u00f3 aut\u00f2noma respecte del consum total de les nostres c\u00e0rregues, poden apar\u00e8ixer diverses problem\u00e0tiques pel que fa a la compensaci\u00f3 de reactiva, que b\u00e0sicament poden resumir-se en les seg\u00fcents:<\/p>\n<p>Un exc\u00e9s inferior de kvarL\u00b7h, a partir dels quals s&#8217;evita la penalitzaci\u00f3 de reactiva:<br \/>\nExc\u00e9s de kvarL\u00b7h sense penalitzaci\u00f3 = 0,33 x kW.h totals per\u00edode tarifari.<\/p>\n<p>&nbsp;<\/p>\n<p>Possibilitat d&#8217;errors de lectura al regulador de reactiva de la bateria de condensadors provocats per:<br \/>\nUna lectura del cos fi del regulador de reactiva diferent del valor comptabilitzat pel comptador de facturaci\u00f3.<br \/>\nUna circulaci\u00f3 de corrent excessivament baixa a trav\u00e9s del transformador o transformadors de corrent que proporciona el mesurament al regulador.<br \/>\nUn valor del cos fi mesurat pel regulador excessivament proper a 0.<\/p>\n<p>Per a una millor comprensi\u00f3 d&#8217;aquest assumpte, a continuaci\u00f3 considerarem diferents possibilitats de connexi\u00f3 i comentarem la possible problem\u00e0tica associada. En tots els casos, s&#8217;assumir\u00e0 que l&#8217;inversor est\u00e0 generant exclusivament pot\u00e8ncia activa (kW), \u00e9s a dir, est\u00e0 configurat per generar en cos phi = 1, tal com determina actualment el REBT. Per tant, tota la pot\u00e8ncia reactiva (generalment inductiva) consumida per les c\u00e0rregues \u00e9s consumida de la xarxa el\u00e8ctrica.[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1684752721839{margin-top: 40px !important;margin-bottom: 20px !important;}&#8221;]Tipologia de connexi\u00f3 n\u00fam. 1[\/vc_column_text][vc_single_image image=&#8221;37881&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1684481066498{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]Els principals riscos associats a aquest mode de connexi\u00f3 serien els seg\u00fcents:<\/p>\n<p>Un exc\u00e9s menor de kvarL.h a partir dels quals s&#8217;evita la penalitzaci\u00f3 de reactiva.<br \/>\nUna lectura del cos fi del regulador de reactiva diferent del valor comptabilitzat pel comptador de facturaci\u00f3.[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;37530&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683698838766{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;37500&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1684481617520{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]L\u2019exemple seg\u00fcent pret\u00e9n aclarir el motiu d&#8217;aquests possibles problemes en una instal\u00b7laci\u00f3 amb les condicions seg\u00fcents de consum estable:<\/p>\n<p>kW III consumits per les c\u00e0rregues: 110 kW<br \/>\nkW III generats per l&#8217;autoconsum: 100 kW<br \/>\nkvarL consumits per les c\u00e0rregues: 93 kvarL<br \/>\nbateria de condensadors existent: 2 x 10 + 4 x 20 kvarC (80 kvarC)<br \/>\ncos fi llegit pel regulador (amb 80 kvarC connectats): 0,99 L<\/p>\n<ul>\n<li>\u00e0rregues: 93 kvarL<\/li>\n<li>bateria de condensadors existent: 2 x 10 + 4 x 20 kvarC (80 kvarC)<\/li>\n<li>cos fi llegit pel regulador (amb 80 kvarC connectats): 0,99 L<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_single_image image=&#8221;37615&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683716804224{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]<\/p>\n<ul>\n<li>cos phi amb l&#8217;autoconsum injectat comptabilitzat pel comptador de la companyia: 0,61<\/li>\n<li><\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_single_image image=&#8221;37518&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683698915019{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]<\/p>\n<ul>\n<li>\n<ul>\n<li>excessos horaris d&#8217;energia reactiva: 13 kvarL.h &#8211; (10 kvarL.h x 0,33) = 9,7 kvarL.h<br \/>\ntensi\u00f3 de xarxa: 3 x 400 VCA<br \/>\nconsiderant 320 h\/mes (P1 a P5):rec\u00e0rrec total en rebut mensual: 9,7 kvarL.h x 320 x 0,062332 \u20ac = 193,5 \u20ac<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1684752787485{margin-top: 40px !important;margin-bottom: 20px !important;}&#8221;]<\/p>\n<h2>Tipologia de connexi\u00f3 #2<\/h2>\n<p>[\/vc_column_text][vc_single_image image=&#8221;37572&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1683713903773{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]Aquest mode de connexi\u00f3 pot presentar alguns problemes en el funcionament de la bateria de condensadors. Els transformadors de corrent que proporcionen senyal de mesurament al regulador autom\u00e0tic nom\u00e9s llegeixen el consum de pot\u00e8ncia activa no generat per l&#8217;autoconsum, i no la totalitat de la pot\u00e8ncia reactiva de les c\u00e0rregues que s\u2019han de compensar. Si el percentatge de la pot\u00e8ncia activa aportada per l&#8217;autoconsum \u00e9s baix o mitj\u00e0 pel que fa al consum total de les c\u00e0rregues, el funcionament del regulador ser\u00e0, amb gran probabilitat, correcte. Per\u00f2 si, en canvi, l&#8217;autogeneraci\u00f3 suposa un gran percentatge del consum total, hi ha un gran risc de mal funcionament del regulador.<\/p>\n<p>Els riscos principals associats a aquest mode de connexi\u00f3 serien els seg\u00fcents:<\/p>\n<p>Un exc\u00e9s inferior de kvarL.h a partir dels quals s&#8217;evita la penalitzaci\u00f3 de reactiva.<br \/>\nUna lectura del cos fi del regulador de reactiva diferent del valor comptabilitzat pel comptador de facturaci\u00f3.<\/p>\n<ul>\n<li><\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;37530&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683698926215{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;37500&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683698936243{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]<\/p>\n<ul>\n<li>Un valor del cos fi mesurat pel regulador excessivament proper a 0.<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_message icon_fontawesome=&#8221;fas fa-clipboard&#8221; css=&#8221;.vc_custom_1684481730527{margin-top: 30px !important;margin-bottom: 30px !important;}&#8221;]Aquest mode de connexi\u00f3 pot presentar problemes en el funcionament de la bateria de condensadors. El transformador o els transformadors de corrent (TC) que proporcionen senyal de mesurament al regulador autom\u00e0tic nom\u00e9s llegeixen el consum de pot\u00e8ncia activa no generat per l&#8217;autoconsum, per\u00f2 s\u00ed que llegeixen la totalitat de la pot\u00e8ncia reactiva de les c\u00e0rregues que s\u2019han de compensar. Si el percentatge de la pot\u00e8ncia activa aportada per l&#8217;autoconsum \u00e9s baix o mitj\u00e0 pel que fa al consum total de les c\u00e0rregues, \u00e9s molt probable que el funcionament del regulador sigui correcte, per\u00f2 si, en canvi, l&#8217;autogeneraci\u00f3 suposa un percentatge elevat del consum total, hi ha un <strong>risc elevat de mal funcionament del regulador.<\/strong>[\/vc_message][vc_column_text]L\u2019exemple seg\u00fcent pret\u00e9n aclarir el motiu d&#8217;aquest possible mal funcionament del regulador, novament en una instal\u00b7laci\u00f3 amb les condicions seg\u00fcents de consum estable:<\/p>\n<ul>\n<li>kW III consumits per les c\u00e0rregues: 110 kW<\/li>\n<li>kW III generats per l&#8217;autoconsum: 102 kW<\/li>\n<li>kvarL consumits per les c\u00e0rregues: 93 kvarL<\/li>\n<li>bateria de condensadors existent: 10 + 4 x 20 kvarC (90 kvarC)<\/li>\n<li>intensitat de corrent a trav\u00e9s de TC (amb 90 kvarC connectats): 12 A<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_single_image image=&#8221;37539&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1683698947982{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]<\/p>\n<ul>\n<li>si suposem un TC de 400\/5 A, 12 A de corrent poden no proporcionar un senyal de mesurament adient al regulador, tant pel que fa a pot\u00e8ncia com a precisi\u00f3\u21d2 <strong>El regulador desconnecta els graons quan detecta una situaci\u00f3 d&#8217;alarma cr\u00edtica per manca de lectura de corrent<\/strong><\/li>\n<li>amb els graons desconnectats, el cos fi llegit pel regulador \u00e9s: 0,08 L<\/li>\n<li>alta possibilitat de <strong>funcionament inestable del regulador, <\/strong>la qual cosa implica que la compensaci\u00f3 de reactiva no es faci de manera efectiva, amb <strong>el risc que s&#8217;apliquin penalitzacions<\/strong> per exc\u00e9s de consum de reactiva inductiva no existents anteriorment<\/li>\n<\/ul>\n<p>Una soluci\u00f3 possible seria intentar evitar almenys el mal funcionament del regulador i es basaria a convertir la tipologia n\u00fam. 2 en la tipologia n\u00fam. 1 per assegurar que el cos fi que mesura el regulador sigui el real de la instal\u00b7laci\u00f3, calculat sobre <strong>el consum total de kW de les c\u00e0rregues que s\u2019han de compensar<\/strong>, amb independ\u00e8ncia de si es consumeix de la xarxa o \u00e9s autogenerat.<\/p>\n<p>Per fer-ho, una opci\u00f3 \u00e9s instal\u00b7lar altres TC que mesurin la pot\u00e8ncia generada per l\u2019autoconsum i portar el seu senyal de secundari, juntament amb els TC de l&#8217;entrada, a un <strong>transformador sumador 5+5\/5 A<\/strong> (model TSR-2 de CIRCUTOR), el senyal de secundari del qual \u00e9s el que proporcionar\u00e0 el mesurament d&#8217;intensitat al regulador de reactiva. D&#8217;acord amb el que s\u2019ha reflectit en la <strong>tipologia de connexi\u00f3 n\u00fam. 3.<\/strong>[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1684752850038{margin-top: 40px !important;margin-bottom: 20px !important;}&#8221;]Tipologia de connexi\u00f3 n\u00fam. 3[\/vc_column_text][vc_single_image image=&#8221;37580&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1683702860950{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]M\u00e8tode de compensaci\u00f3 avan\u00e7at<\/p>\n<p>La soluci\u00f3 m\u00e9s efectiva, i que asseguraria una compensaci\u00f3 correcta de reactiva amb independ\u00e8ncia de l&#8217;estat de funcionament, caracter\u00edstiques i punt de connexi\u00f3 del sistema d&#8217;autoconsum, \u00e9s la instal\u00b7laci\u00f3, com a sistema complementari de compensaci\u00f3, de generadors est\u00e0tics de reactiva model SVGm.<br \/>\nUna an\u00e0lisi detallada de les necessitats de compensaci\u00f3 ens ajudar\u00e0 a determinar l&#8217;equip SVGm m\u00e9s adient per ser implementat a la nostra instal\u00b7laci\u00f3 i evitar les penalitzacions que puguin apar\u00e8ixer i no siguin eludibles amb un sistema convencional de bateria de condensadors. Aquesta an\u00e0lisi tamb\u00e9 serveix per determinar la viabilitat econ\u00f2mica de la instal\u00b7laci\u00f3.<br \/>\nLes prestacions principals d&#8217;aquests equips generadors est\u00e0tics de reactiva SVGm s\u00f3n les enumerades a continuaci\u00f3:<\/p>\n<p>Capacitat d&#8217;injecci\u00f3 de pot\u00e8ncia reactiva (compensaci\u00f3) en qualsevol condici\u00f3 de corrent a trav\u00e9s dels TC.<br \/>\nAjustament prec\u00eds de la injecci\u00f3 de pot\u00e8ncia reactiva per aconseguir arribar al cos fi objectiu, ja que no es tracta d&#8217;un sistema basat en graons de condensador.<br \/>\nResposta immediata a les variacions de c\u00e0rrega, lliure de transitoris, i immune al contingut harm\u00f2nic de la xarxa.<\/p>\n<p>Una tipologia de connexi\u00f3 possible de l&#8217;equip SVGm a la nostra xarxa el\u00e8ctrica seria la indicada en la tipologia n\u00fam. 4, per\u00f2 n\u2019hi ha d\u2019altres, en funci\u00f3 dels requisits espec\u00edfics que presenti cada instal\u00b7laci\u00f3, i que han de ser analitzats de manera particular per a cada cas.[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1684752879020{margin-top: 40px !important;margin-bottom: 20px !important;}&#8221;]Tipologia de connexi\u00f3 n\u00fam. 4[\/vc_column_text][vc_single_image image=&#8221;37564&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1683702873358{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]Conclusions generals sobre la compensaci\u00f3 de reactiva a instal\u00b7lacions on s&#8217;ha incorporat un sistema d&#8217;autoconsum<\/p>\n<p>Podr\u00edem enumerar les seg\u00fcents consideracions principals sobre aquest tema:<\/p>\n<p>La reducci\u00f3 de l&#8217;energia activa (kWh) comptabilitzada pel comptador de facturaci\u00f3 ocasiona els principals problemes que poden succeir, per tant, a m\u00e9s percentatge de generaci\u00f3 per autoconsum respecte al consum total de la instal\u00b7laci\u00f3 (receptors), m\u00e9s probabilitat d&#8217;aparici\u00f3 d&#8217;aquests problemes.<br \/>\nEn funci\u00f3 de la causa i gravetat del problema amb la compensaci\u00f3 de reactiva, es poden considerar diferents solucions. Entre elles es pot contemplar:<br \/>\nLa modificaci\u00f3 del punt d&#8217;injecci\u00f3 de l&#8217;autoconsum a la xarxa.<br \/>\nAddici\u00f3 de transformadors de corrent de mesura de la injecci\u00f3 de pot\u00e8ncia a xarxa.<br \/>\nLa modificaci\u00f3 de la pot\u00e8ncia de la bateria existent:<\/p>\n<p>Augment de la pot\u00e8ncia de la bateria per aconseguir un cos fi total mitj\u00e0 el m\u00e9s proper possible a 1 en diferents condicions de consum de les c\u00e0rregues i injecci\u00f3 de l&#8217;autoconsum.<br \/>\nL&#8217;addici\u00f3 de graons de menor pot\u00e8ncia que el menor actual de la bateria per possibilitar la compensaci\u00f3 de consums m\u00e9s petits de kvarL que ara s\u00ed que poden suposar una penalitzaci\u00f3. B\u00e0sicament disposar de graons de pot\u00e8ncies menors per a un ajustament m\u00e9s prec\u00eds<br \/>\nInstal\u00b7lar compensacions individuals en maquin\u00e0ria o subquadres que complementin la compensaci\u00f3 de reactiva general efectuada per la bateria autom\u00e0tica en cap\u00e7alera.<br \/>\nEquipar la bateria amb un regulador de la gamma Computer SMART III, capa\u00e7 de mesurar l&#8217;energia reactiva consumida per les 3 fases, exactament igual que el comptador de companyia, per aconseguir aix\u00ed una compensaci\u00f3 de reactiva m\u00e9s eficient i precisa.<br \/>\nUtilitzar, en tot cas, un regulador amb capacitat de mesura als 4 quadrants de l&#8217;energia, \u00e9s a dir, tant en condici\u00f3 de consum de la xarxa com de generaci\u00f3. Aquesta caracter\u00edstica \u00e9s especialment essencial en el cas dels sistemes d&#8217;autoconsums on hi pugui haver exportaci\u00f3 d&#8217;energia a la xarxa. Si b\u00e9 en el present nom\u00e9s sembla que es registren els consums als quadrants de consum (Q1 & Q4), se&#8217;n recomana indiscutiblement l&#8217;\u00fas tant per preveure possibles modificacions futures del sistema de facturaci\u00f3, com per evitar un funcionament erroni del propi regulador. Recordar, en aquest sentit, que tots els reguladors de CIRCUTOR de les darreres gammes inclouen la mesura en els 4 quadrants.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=&#8221;.vc_custom_1684752945456{margin-top: 40px !important;margin-bottom: 40px !important;}&#8221;]Conclusions generals sobre la compensaci\u00f3 de reactiva en instal\u00b7lacions on s&#8217;ha incorporat un sistema d&#8217;autoconsum[\/vc_column_text][vc_btn title=&#8221;M\u00e9s informaci\u00f3 autoconsum d&#8217;energia&#8221; style=&#8221;custom&#8221; custom_background=&#8221;#e40040&#8243; custom_text=&#8221;#ffffff&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fcircutor.com%2Fsectores%2Fautoconsumo-de-energia%2F|target:_blank&#8221;][vc_separator css=&#8221;.vc_custom_1683713324472{margin-top: 40px !important;margin-bottom: 40px !important;}&#8221;][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1683702748350{margin-top: 40px !important;margin-bottom: 40px !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;37763&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221; img_link_target=&#8221;_blank&#8221; css=&#8221;.vc_custom_1684158691743{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]Regulador d&#8217;energia reactiva Computer C Wi-fi<\/p>\n<p>&nbsp;<\/p>\n<p>El regulador \u00e9s l&#8217;element clau per gestionar la compensaci\u00f3 de reactiva inductiva i assegurar el funcionament de les bateries mitjan\u00e7ant diferents avisos i alarmes que n\u2019assegurin la supervisi\u00f3, el monitoratge i el control correctes.[\/vc_column_text][vc_btn title=&#8221;M\u00e1s informaci\u00f3n&#8221; color=&#8221;primary&#8221; align=&#8221;center&#8221; link=&#8221;url:%2Fproductos%2Fcompensacion-de-energia-reactiva-y-filtrado-de-armonicos%2Freguladores-de-energia-reactiva%2Freguladores-automaticos-energia-reactiva-con-comunicaciones%2Fserie%2Fcomputer-c-wi-fi%2F&#8221; css=&#8221;.vc_custom_1684158726707{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;37771&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221; img_link_target=&#8221;_blank&#8221; css=&#8221;.vc_custom_1684158701198{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]<strong>Gamma de transformadors per al mesurament de corrent<\/strong><\/p>\n<p>La instal\u00b7laci\u00f3 de transformadors de corrent permet que els diferents equips de mesurament proporcionin dades fiables i tra\u00e7ables sobre l&#8217;evoluci\u00f3 de consums i processos productius a les instal\u00b7lacions el\u00e8ctriques.[\/vc_column_text][vc_btn title=&#8221;M\u00e1s informaci\u00f3n&#8221; color=&#8221;primary&#8221; align=&#8221;center&#8221; link=&#8221;url:%2Fproductos%2Fmedida-y-control%2Ftransformadores-de-corriente-y-shunts%2F&#8221; css=&#8221;.vc_custom_1684158734625{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;37139&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221; img_link_target=&#8221;_blank&#8221; css=&#8221;.vc_custom_1684158712918{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][vc_column_text]<strong>Gamma de transformadors sumadors de corrent<\/strong><\/p>\n<p>Usats per sumar el corrent de diverses l\u00ednies el\u00e8ctriques de corrent altern per obtenir un corrent de sortida com\u00fa proporcional a la suma del de totes les l\u00ednies. Permet mesurar el corrent de diverses l\u00ednies en un sol equip.[\/vc_column_text][vc_btn title=&#8221;M\u00e1s informaci\u00f3n&#8221; color=&#8221;primary&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fcircutor.com%2Fproductos%2Ftransformadores-de-corriente-y-shunts%2Fotros-accesorios-de-transformadores-de-medida%2Ftransformador-sumador%2Fproduct%2FM70701.%2F&#8221; css=&#8221;.vc_custom_1684158747026{margin-top: 20px !important;margin-bottom: 20px !important;}&#8221;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]El desenvolupament r\u00e0pid dels components principals dels sistemes fotovoltaics d&#8217;autoconsum cap a equips m\u00e9s eficients i menys costosos (tant pel que fa a les plaques de generaci\u00f3 fotovoltaica com als inversors per a la conversi\u00f3 CC\/CA) i la modificaci\u00f3 raonable i esperada de la regulaci\u00f3 nacional (que ha flexibilitzat i simplificat de manera significativa els [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":37894,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3710],"tags":[3721,3723,3725,3726],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#039;energia reactiva - CIRCUTOR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/ca\/articles\/les-instal\u00b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\" \/>\n<meta property=\"og:locale\" content=\"ca_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#039;energia reactiva - CIRCUTOR\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column][vc_column_text]El desenvolupament r\u00e0pid dels components principals dels sistemes fotovoltaics d&#8217;autoconsum cap a equips m\u00e9s eficients i menys costosos (tant pel que fa a les plaques de generaci\u00f3 fotovoltaica com als inversors per a la conversi\u00f3 CC\/CA) i la modificaci\u00f3 raonable i esperada de la regulaci\u00f3 nacional (que ha flexibilitzat i simplificat de manera significativa els [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/ca\/articles\/les-instal\u00b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-17T08:08:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-05-29T14:37:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2021\/01\/FSB_MontajeFVsolar.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Circutor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@circutor\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Escrit per\" \/>\n\t<meta name=\"twitter:data1\" content=\"Circutor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Temps estimat de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minuts\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"ca\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\",\"url\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\",\"name\":\"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d'energia reactiva - CIRCUTOR\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2023-05-17T08:08:15+00:00\",\"dateModified\":\"2023-05-29T14:37:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#breadcrumb\"},\"inLanguage\":\"ca\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/ca\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#8217;energia reactiva\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\"},\"author\":{\"name\":\"Circutor\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/234a865ed449be1116408bdfdf6f576a\"},\"headline\":\"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#8217;energia reactiva\",\"datePublished\":\"2023-05-17T08:08:15+00:00\",\"dateModified\":\"2023-05-29T14:37:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/\"},\"wordCount\":2912,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"keywords\":[\"Autoconsum\",\"Compensaci\u00f3 reactiva\",\"Distribuci\u00f3 energia\",\"Energies renovables\"],\"articleSection\":[\"Articles\"],\"inLanguage\":\"ca\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#respond\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/234a865ed449be1116408bdfdf6f576a\",\"name\":\"Circutor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png\",\"caption\":\"Circutor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d'energia reactiva - CIRCUTOR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/ca\/articles\/les-instal\u00b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/","og_locale":"ca_ES","og_type":"article","og_title":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d'energia reactiva - CIRCUTOR","og_description":"[vc_row][vc_column][vc_column_text]El desenvolupament r\u00e0pid dels components principals dels sistemes fotovoltaics d&#8217;autoconsum cap a equips m\u00e9s eficients i menys costosos (tant pel que fa a les plaques de generaci\u00f3 fotovoltaica com als inversors per a la conversi\u00f3 CC\/CA) i la modificaci\u00f3 raonable i esperada de la regulaci\u00f3 nacional (que ha flexibilitzat i simplificat de manera significativa els [&hellip;]","og_url":"https:\/\/circutor.com\/ca\/articles\/les-instal\u00b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_published_time":"2023-05-17T08:08:15+00:00","article_modified_time":"2023-05-29T14:37:48+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2021\/01\/FSB_MontajeFVsolar.jpg","type":"image\/jpeg"}],"author":"Circutor","twitter_card":"summary_large_image","twitter_creator":"@circutor","twitter_site":"@circutor","twitter_misc":{"Escrit per":"Circutor","Temps estimat de lectura":"14 minuts"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"ca"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/","url":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/","name":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d'energia reactiva - CIRCUTOR","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2023-05-17T08:08:15+00:00","dateModified":"2023-05-29T14:37:48+00:00","breadcrumb":{"@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#breadcrumb"},"inLanguage":"ca","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/ca\/"},{"@type":"ListItem","position":2,"name":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#8217;energia reactiva"}]},{"@type":"Article","@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#article","isPartOf":{"@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/"},"author":{"name":"Circutor","@id":"https:\/\/circutor.com\/#\/schema\/person\/234a865ed449be1116408bdfdf6f576a"},"headline":"Les instal\u00b7lacions amb autoconsum i el seu efecte sobre els sistemes de compensaci\u00f3 d&#8217;energia reactiva","datePublished":"2023-05-17T08:08:15+00:00","dateModified":"2023-05-29T14:37:48+00:00","mainEntityOfPage":{"@id":"https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/"},"wordCount":2912,"commentCount":0,"publisher":{"@id":"https:\/\/circutor.com\/#organization"},"keywords":["Autoconsum","Compensaci\u00f3 reactiva","Distribuci\u00f3 energia","Energies renovables"],"articleSection":["Articles"],"inLanguage":"ca","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/circutor.com\/ca\/articles\/les-instal%c2%b7lacions-amb-autoconsum-i-el-seu-efecte-sobre-els-sistemes-de-compensacio-denergia-reactiva-2\/#respond"]}]},{"@type":"Person","@id":"https:\/\/circutor.com\/#\/schema\/person\/234a865ed449be1116408bdfdf6f576a","name":"Circutor","image":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/circutor.com\/#\/schema\/person\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/04\/usuario-logo-gris-96x96.png","caption":"Circutor"}}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/posts\/37893"}],"collection":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/comments?post=37893"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/posts\/37893\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/media\/37894"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/media?parent=37893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/categories?post=37893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/tags?post=37893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}