{"id":39887,"date":"2023-07-10T12:38:41","date_gmt":"2023-07-10T10:38:41","guid":{"rendered":"https:\/\/circutor.com\/?page_id=39887"},"modified":"2023-07-12T15:17:40","modified_gmt":"2023-07-12T13:17:40","slug":"preguntes-frequents","status":"publish","type":"page","link":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/","title":{"rendered":"Preguntes freq\u00fcents"},"content":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;banner_pagina_texto&#8221; css=&#8221;.vc_custom_1662460257542{background-image: url(https:\/\/circutor.com\/wp-content\/uploads\/2022\/09\/FSB_FAQS.jpg?id=28416) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_column css=&#8221;.vc_custom_1605620904006{padding-top: 0px !important;}&#8221;][vc_row_inner el_class=&#8221;breadcrumb&#8221;][vc_column_inner]<div itemscope itemtype=\"https:\/\/schema.org\/BreadcrumbList\" id=\"breadcrumb\"><div itemprop=\"itemListElement\" itemscope itemtype=\"https:\/\/schema.org\/ListItem\"><a itemprop=\"item\" href=\"https:\/\/circutor.com\/ca\/\"><span itemprop=\"name\">Home<\/span><\/a><meta itemprop=\"position\" content=\"1\" \/><\/div><div itemprop=\"itemListElement\" itemscope itemtype=\"https:\/\/schema.org\/ListItem\"><span><i class=\"ico-guil-singl-right\"><\/i><\/span><a itemprop=\"item\" href=\"https:\/\/circutor.com\/ca\/suport\/\"><span itemprop=\"name\">Suport<\/span><\/a><meta itemprop=\"position\" content=\"3\"><\/div><div itemprop=\"itemListElement\" itemscope itemtype=\"https:\/\/schema.org\/ListItem\"><span><i class=\"ico-guil-singl-right\"><\/i><\/span><span class=\"active_item_breadcrumb\" itemprop=\"name\">Preguntes freq\u00fcents<\/span><meta itemprop=\"position\" content=\"4\"><\/div><\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h1>Soluci\u00f3 a les preguntes m\u00e9s habituals<\/h1>\n<p>En aquesta p\u00e0gina pots trobar resposta a temes que et poden interessar. Per exemple, com configurar les comunicacions d&#8217;un CVM, qu\u00e8 fer si la mesura no \u00e9s correcta, etc.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_class=&#8221;bloque&#8221;][vc_column][vc_column_text]<\/p>\n<h6 class=\"wrap-title\">RESPOSTES<\/h6>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;desplegar_acordeon_faq&#8221;][vc_column][vc_row_inner el_class=&#8221;abrir_acordeon_faq&#8221;][vc_column_inner el_class=&#8221;left&#8221; width=&#8221;1\/2&#8243;][vc_column_text]PowerStudio[\/vc_column_text][\/vc_column_inner][vc_column_inner el_class=&#8221;right&#8221; width=&#8221;1\/2&#8243;][vc_raw_html]JTNDaSUyMGNsYXNzJTNEJTIyaWNvLXVwLWFycm93aGVhZCUyMiUzRSUzQyUyRmklM0U=[\/vc_raw_html][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_class=&#8221;acordeon_faq&#8221;][vc_column width=&#8221;1\/6&#8243;][\/vc_column][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h6 class=\"wrap-title\">CLIENT<\/h6>\n<p>[\/vc_column_text][vc_tta_accordion style=&#8221;modern&#8221; shape=&#8221;square&#8221; color=&#8221;white&#8221; c_icon=&#8221;chevron&#8221; active_section=&#8221;-1&#8243; el_class=&#8221;acordeon_preguntas_frecuentes&#8221;][vc_tta_section title=&#8221;No puc veure l&#8217;applet. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615892222551-dbec634f-66ba&#8221;][vc_column_text]Heu de comprovar que en l&#8217;ordinador local hi hagi instal\u00b7lat el navegador Microsoft Internet Explorer, Netscape (Mozilla) o Firefox. Assegureu-vos de tenir instal\u00b7lada la m\u00e0quina virtual JRE de Java 1.6 (6.0) o superior, tot i que en cas de no estar instal\u00b7lada el propi navegador oferir\u00e0 informaci\u00f3 i guiar\u00e0 en el proc\u00e9s de la seva d&#8217;instal\u00b7laci\u00f3.<\/p>\n<p>Si l&#8217;Applet apareix per\u00f2 mostra un missatge avisant de que \u201cno s&#8217;ha pogut comunicar amb el servidor\u201d o \u201cno s&#8217;ha pogut recuperar la informaci\u00f3 requerida\u201d assegureu-vos de que el motor de comunicacions est\u00e0 en execuci\u00f3.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;L&#8217;applet no mostra els textos correctament. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896630122-88a8b0cd-3669&#8243;][vc_column_text]\u00c9s possible que alguns tipus de lletra que es van aplicar als controls al dissenyar un informe o una pantalla SCADA no existeixin en la m\u00e0quina des de que es descarrega l&#8217;Applet i, per tant, el tipus de lletra escollit pot ser notablement diferent a l&#8217;original.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Algun succ\u00e9s no es comporta com s&#8217;esperava. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896641272-f40191e5-3475&#8243;][vc_column_text]Si el succ\u00e9s no es produeix quan creieu que s&#8217;hauria de produir, o viceversa, comproveu que la condici\u00f3 es pot complir alguna vegada i assegureu-vos que el succ\u00e9s est\u00e0 habilitat en algun moment per calendari i que la condici\u00f3 es pot complir durant aquest interval. Comproveu que els dispositius involucrats en l&#8217;avaluaci\u00f3 de la condici\u00f3 del succ\u00e9s comuniquen correctament i assegureu-vos que el motor de comunicacions s&#8217;ha iniciat. Comproveu que teniu permisos per veure aquest tipus d&#8217;esdeveniments i que heu marcat la casella de notificar i\/o registrar.<\/p>\n<p>Si el succ\u00e9s sembla no haver realitzat les accions que han estat definides comproveu a la llista d&#8217;esdeveniments que realment s&#8217;ha produ\u00eft. Si tot i aix\u00ed no s&#8217;ha produ\u00eft l&#8217;acci\u00f3 o les accions programades comproveu que els equips sobre els quals s&#8217;hauria d&#8217;haver actuat estan encesos i comuniquen correctament. En cas que l&#8217;acci\u00f3 fos l&#8217;execuci\u00f3 d&#8217;una aplicaci\u00f3 externa comproveu que aquesta aplicaci\u00f3 est\u00e0 correctament instal\u00b7lada i que l&#8217;ordre i els par\u00e0metres s\u00f3n els correctes (podeu posar aquesta acci\u00f3 en un control d&#8217;execuci\u00f3 a una pantalla de SCADA de prova per veure si es comporta de la manera esperada).[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;La visualitzaci\u00f3 dels valors no \u00e9s l&#8217;esperada. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896652395-9bde392a-8ec3&#8243;][vc_column_text]\u00c9s possible que un control condicional o una f\u00f3rmula facin refer\u00e8ncia a alguna variable d&#8217;un dispositiu que no comunica o que encara no s&#8217;ha pogut interrogar per primera vegada. En una pantalla SCADA, si es tracta d&#8217;una condici\u00f3 no apareixer\u00e0 res i si es tracta d&#8217;una f\u00f3rmula apareixer\u00e0 un gui\u00f3 (\u201c-\u201d) fins que se&#8217;n pugui inicialitzar el valor. En un informe, si no hi ha dades en aquest per\u00edode i no es pot avaluar la condici\u00f3 d&#8217;un control condicional no apareixer\u00e0 res i, si no es pot avaluar una f\u00f3rmula, apareixer\u00e0 la seva definici\u00f3.<\/p>\n<p>Pot ser que a l&#8217;avaluar la f\u00f3rmula es trobi alguna operaci\u00f3 no v\u00e0lida, com l&#8217;arrel quadrada d&#8217;un nombre negatiu o la divisi\u00f3 per zero, en aquest cas a la pantalla SCADA apareixer\u00e0 un interrogant (\u201c?\u201d) i a l&#8217;informe apareixer\u00e0 la definici\u00f3 de la f\u00f3rmula. Si el que no es pot avaluar \u00e9s la condici\u00f3 d&#8217;un control condicional no apareixer\u00e0 res.<\/p>\n<p>Pot ser que l&#8217;avaluaci\u00f3 de l&#8217;expressi\u00f3 d&#8217;una f\u00f3rmula no sigui representable, ja sigui per la configuraci\u00f3 del control que la cont\u00e9, ja sigui perqu\u00e8 l&#8217;avaluaci\u00f3 d&#8217;aquesta f\u00f3rmula ha tornat un valor fora de rang. En aquest cas apareixer\u00e0 el car\u00e0cter \u201c#\u201d.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;La gr\u00e0fica no es pinta correctament. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896675516-db907f30-fad9&#8243;][vc_column_text]Si a la gr\u00e0fica semblen faltar-hi punts comproveu que aix\u00f2 no sigui pel fet que es representen variables amb per\u00edodes diferents.<\/p>\n<p>Si las gr\u00e1ficas de barras tienen anchos que no son correctos aseg\u00farese de que los valores est\u00e1n separados por la distancia que marca el periodo del driver. As\u00ed, por ejemplo, si un dispositivo guarda datos cada 5 minutos y cambiamos el periodo a 15 minutos, al visualizar las gr\u00e1ficas de barras de los valores anteriores al cambio de periodo (cada 5 minutos) las barras se sobrepondr\u00e1n unas a otras. Si cambiamos el periodo a un valor menos, las barras antes del cambio aparecer\u00e1n m\u00e1s estrechas de lo que ser\u00eda necesario. En cualquier caso las gr\u00e1ficas de barras de valores separados por la distancia marcada en el periodo de registro del Driver aparecer\u00e1n siempre correctamente.<\/p>\n<p>Si les gr\u00e0fiques de barres tenen amplades que no s\u00f3n correctes assegureu-vos que els valors estan separats per la dist\u00e0ncia que marca el per\u00edode del driver. Aix\u00ed, per exemple, si un dispositiu guarda dades cada 5 minuts i canviem el per\u00edode a 15 minuts, en visualitzar les gr\u00e0fiques de barres dels valors anteriors al canvi de per\u00edode (cada 5 minuts) les barres se sobreposaran les unes a les altres. Si canviem el per\u00edode a un valor menys, les barres abans del canvi apareixeran m\u00e9s estretes del que caldria. En qualsevol cas, les gr\u00e0fiques de barres de valors separades per la dist\u00e0ncia marcada en el per\u00edode de registre del Driver apareixeran sempre correctament.<\/p>\n<p>Si no veieu valors on creieu que hauria d&#8217;haver-ne assegureu-vos que no teniu cap zoom en una zona sense valors o que l&#8217;eix Y no est\u00e0 for\u00e7at a uns nivells per als quals no hi ha valors.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;El pot de pintura no actua correctament. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896683136-a537da89-2bcd&#8221;][vc_column_text]Si al posar un control de pot de pintura en una pantalla Scada no es comporta de la manera esperada assegureu-vos de:<\/p>\n<ol>\n<li>La condici\u00f3 o condicions definides s\u00f3n les correctes per a cada color.<\/li>\n<li>La zona on ha col\u00b7locat el control cont\u00e9 un color homogeni. \u00c9s possible que la zona sobre la qual est\u00e0 col\u00b7locat el pot de pintura contingui punts de diferents colors encara que de tonalitats molt semblants, de manera que a simple vista semblin iguals. El control de pot de pintura es propaga nom\u00e9s a trav\u00e9s de colors id\u00e8ntics.<\/li>\n<li>La zona que voleu omplir amb els colors definits en el control no forma part d&#8217;un altre control. El control de pot de pintura nom\u00e9s interacciona amb el fons de pantalla i no t\u00e9 en compte cap dels altres controls. No intenteu omplir amb un pot de pintura, per exemple, una imatge afegida mitjan\u00e7ant el control de tipus imatge.<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;El programari no envia correus. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896700161-f91693d7-3aba&#8221;][vc_column_text]Per q\u00fcestions de seguretat, el programari no envia correus si el servidor de correu no t\u00e9 activada l&#8217;opci\u00f3 <em>Transport Layer Security<\/em> (TSL) i el servidor de correu nom\u00e9s suporta els protocols d&#8217;autenticaci\u00f3 Plain, Login o NTLM, ja que aquests protocols s\u00f3n poc segurs per enviar informaci\u00f3.<\/p>\n<p>Si aquest \u00e9s el vostre cas:<\/p>\n<ul>\n<li>Per augmentar la seguretat del vostre servidor de correu i per tal que el programari permeti enviar els correus, cal habilitar l&#8217;encriptaci\u00f3 per TLS\/SSL. Si es vol, es pot afegir un altre m\u00e8tode d&#8217;autenticaci\u00f3 com ara cram-md5, digest-md5, gssapi o external.<\/li>\n<li>Si NO s&#8217;ha activat el TLS cal afegir un dels protocols d&#8217;autenticaci\u00f3 proposats anteriorment, podent mantenir els protocols que ja estaven funcionant al servidor de correu, ja que no seran usats pel programari. El protocol d&#8217;autenticaci\u00f3 del servidor smtp NO podr\u00e0 ser cap dels seg\u00fcents: plain, login o ntlm.<\/li>\n<li>Si segueix sense enviar correus comproveu que el vostre servidor de correu electr\u00f2nic tingui un usuari amb el mateix nom que l&#8217;adre\u00e7a configurada. El programari utilitzar\u00e0 com a usuari el correu electr\u00f2nic configurat.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Puc llan\u00e7ar aplicacions externes des de l&#8217;Applet?&#8221; tab_id=&#8221;1615896711948-5c6154bb-3d22&#8243;][vc_column_text]Per q\u00fcestions de seguretat, els Applet Java tenen unes limitacions for\u00e7a importants relatives a l&#8217;acc\u00e9s als recursos de la m\u00e0quina local on s&#8217;executen. Una d&#8217;aquestes restriccions \u00e9s la de no poder executar aplicacions a la m\u00e0quina local. No obstant aix\u00f2, aquesta restricci\u00f3 es pot desactivar afegint al fitxer de permisos java.policy situat a la instal\u00b7laci\u00f3 de la m\u00e0quina virtual JRE, la seg\u00fcent l\u00ednia:<\/p>\n<ul>\n<li>permission java.io.FilePermission &#8220;&lt;&gt;&#8221;, &#8220;execute&#8221;;<\/li>\n<\/ul>\n<p>Cal assenyalar, per\u00f2, que a l&#8217;Applet no es poden visualitzar directament fitxers des del control d&#8217;execuci\u00f3, com es pot fer a l&#8217;SCADA. Aix\u00ed, si volgu\u00e9ssim mostrar una imatge a l&#8217;Applet no n&#8217;hi hauria prou amb posar el nom de la imatge al control d&#8217;execuci\u00f3, sin\u00f3 que haur\u00edem de posar l&#8217;aplicaci\u00f3 que volem utilitzar per mostrar la imatge i, com a par\u00e0metre, la imatge a mostrar.<\/p>\n<p><strong>Nota<\/strong>: L&#8217;opci\u00f3 de llan\u00e7ar aplicacions externes \u00e9s molt dependent del sistema en qu\u00e8 s&#8217;executi l&#8217;Applet, de manera que \u00e9s molt probable que nom\u00e9s funcioni en el sistema per al qual ha estat desenvolupada l&#8217;aplicaci\u00f3.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc veure l&#8217;Applet des d&#8217;una m\u00e0quina que no sigui Windows?&#8221; tab_id=&#8221;1615896725119-db8f6121-f4c4&#8243;][vc_column_text]L&#8217;Applet es pot visualitzar sense fer cap acci\u00f3 especial des de tots els sistemes operatius que disposin d&#8217;una implementaci\u00f3 de la m\u00e0quina virtual Java 1.5 (5.0) o superior i un navegador HTML. Entre d&#8217;altres, complirien aquests requisits els sistemes operatius seg\u00fcents: Windows, Linux, Solaris SPARC, Solaris x86, Solaris AMD64, Linux AMD64, etc.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc dibuixar una l\u00ednia en un informe o una pantalla Scada?&#8221; tab_id=&#8221;1615896734976-9fe4466a-4dbe&#8221;][vc_column_text]Tot i que no hi ha una eina espec\u00edfica per dibuixar l\u00ednies, \u00e9s possible obtenir aquesta prestaci\u00f3 de dues maneres diferents:<\/p>\n<ol>\n<li>Dibuixeu les l\u00ednies que vulgueu a la imatge de fons amb anterioritat.<\/li>\n<li>Si el que voleu \u00e9s dibuixar l\u00ednies verticals i\/o horitzontals i no us resulta pr\u00e0ctic utilitzar el m\u00e8tode anterior, \u00e9s possible obtenir aquesta prestaci\u00f3 mitjan\u00e7ant un senzill truc. El procediment consisteix a obtenir una imatge d&#8217;un quadrat o rectangle s\u00f2lid del color que voleu per a la l\u00ednia (pot fins i tot consistir en una imatge d&#8217;un simple p\u00edxel). Despr\u00e9s afegiu un control d&#8217;imatge i assigneu-li el quadrat anterior. Deshabiliteu els camps de \u201cMantenir mida real\u201d i de \u201cMantenir proporcions\u201d i estireu el control fins a obtenir la l\u00ednia horitzontal i\/o vertical del gruix desitjat.<\/li>\n<li>Afegiu un control de text i escriviu el text \u201c________\u201d (caracters de subratllat i tan llarg com necessiteu) Aix\u00f2 genera una l\u00ednia horitzontal. Aquest m\u00e8tode t\u00e9 l&#8217;avantatge que permet realitzar l\u00ednies diagonals o verticals aplicant rotaci\u00f3 al text (90 o 270 graus per a l\u00ednies verticals), canviar-li el color i tamb\u00e9 permet modificar-ne el gruix modificant la mida.<\/li>\n<\/ol>\n<p>[\/vc_column_text][vc_single_image image=&#8221;1796&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616742711306{margin-top: 20px !important;}&#8221;][\/vc_tta_section][vc_tta_section title=&#8221;Estic creant la meva primera pantalla o informe i no puc afegir una imatge de fons ni una imatge fixa. Qu\u00e8 est\u00e0 passant?&#8221; tab_id=&#8221;1615896745866-de9c165b-6024&#8243;][vc_column_text]Debe recordar que las im\u00e1genes que se pueden incluir en las pantallas Scada y en los informes deben haberse a\u00f1adido anteriormente a trav\u00e9s del gestor de im\u00e1genes. As\u00ed que es necesario antes de empezar a dise\u00f1ar una pantalla o informe a\u00f1adir las im\u00e1genes que vaya a necesitar a trav\u00e9s del gestor de im\u00e1genes.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Qu\u00e8 es pot \u201ccomptar\u201d?&#8221; tab_id=&#8221;1615896753796-e8d217aa-3c50&#8243;][vc_column_text]Cualquier suceso a\u00f1adido al sistema contiene una variable que indica cuantas veces se ha activado, cuantas veces se ha reconocido, cuantas veces se ha desactivado, cuanto tiempo ha estado activo, si est\u00e1 activo en este momento y cuanto tiempo lleva activo desde la \u00faltima vez que se activ\u00f3.<\/p>\n<p>Puede contarse tambi\u00e9n cuantas veces se ha producido algo durante la hora en curso, el d\u00eda en curso, etc. Para ello re crear\u00e1 una variable calculable forzable inicializada a 0 y un suceso que cuando se cumpla una condici\u00f3n realice la acci\u00f3n de forzar esa variable a su mismo valor m\u00e1s una unidad.<\/p>\n<p><strong>[R$CAL_FORZABLES.CONTADOR1]=[R$CAL_FORZABLES.CONTADOR1]+1<\/strong><\/p>\n<p>S\u00f3lo nos faltar\u00eda a\u00f1adir un suceso que hiciera un reset de ese contador a 0 cuando la fecha fuera las XX\/XX\/XXXX 00:00:00 (las 00:00:00 horas de cada d\u00eda) con lo cual el contador tendr\u00eda el n\u00famero de activaciones del d\u00eda en curso. El reset de este contador podr\u00eda hacerse con un control de forzado de variable en una pantalla Scada, siendo en este caso manual en vez de autom\u00e1tico.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;M&#8217;agradaria exportar les dades d&#8217;un informe per poder processar-los despr\u00e9s. Com puc fer-ho?&#8221; tab_id=&#8221;1615896763428-d7aeb6b2-9657&#8243;][vc_column_text]Los datos que se muestran en un informe son datos hist\u00f3ricos agrupados por el periodo del informe, por lo tanto tenemos un valor por periodo (en caso de ser una expresi\u00f3n en la que est\u00e1n involucradas varias variables se recupera el valor de cada variable para el periodo del informe y se eval\u00faa la expresi\u00f3n).<\/p>\n<p>A efectos pr\u00e1cticos, los valores de las variables que se usan en los informes pueden ser consultados mediante la petici\u00f3n \/services\/user\/records.xml (que est\u00e1 documentada en la secci\u00f3n de peticiones XML de usuario).<\/p>\n<p>Imaginemos entonces que tenemos un informe con el siguiente aspecto:[\/vc_column_text][vc_single_image image=&#8221;1800&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616742858261{margin-top: 20px !important;}&#8221;][vc_column_text]El informe est\u00e1 agrupado por d\u00eda, en concreto estamos visualizando el d\u00eda 11 de junio. Se muestra que hay una serie de valores en rojo, dentro de unas cajas, el primer valor de arriba a la izquierda corresponde a la variable \u201cCVM K 2.VI1\u201d.<\/p>\n<p>Para poder consultar ese valor mediante una petici\u00f3n HTTP\/XML al servidor podemos hacer lo siguiente:<\/p>\n<ul>\n<li>http:\/\/192.168.5.52\/services\/user\/records.xml?begin=10062008220000?end=11062008220000?period=ALL?var=CVM K 2.VI1<\/li>\n<\/ul>\n<p>Esta petici\u00f3n, si la realizamos con el navegador, devolver\u00e1 algo como lo siguiente:[\/vc_column_text][vc_single_image image=&#8221;1802&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616742898296{margin-top: 20px !important;}&#8221;][vc_column_text]<strong>Resultado de la petici\u00f3n en el navegador Internet Explorer<\/strong><\/p>\n<p>Donde, en el campo \u201cvalue\u201c tenemos el valor que queremos. Esta petici\u00f3n puede realizarse directamente desde, por ejemplo, la hoja de c\u00e1lculo Excel, simplemente escribiendo esta petici\u00f3n en el di\u00e1logo de \u201cAbrir\u201d (en vez del nombre de un fichero). Excel interpretar\u00e1 el XML anterior y generar\u00e1 una tabla con los datos:[\/vc_column_text][vc_single_image image=&#8221;1804&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616742950575{margin-top: 20px !important;}&#8221;][vc_column_text]<strong>Petici\u00f3n \u201cabierta\u201d con Excel 2003. En D1 tenemos el dato<\/strong>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;He intentat fer una taula amb el client i m&#8217;apareix el missatge \u201cTaula massa gran\u201d. Qu\u00e8 puc fer per poder veure-la?&#8221; tab_id=&#8221;1615896773397-77f29eea-d21d&#8221;][vc_column_text]El cliente es una aplicaci\u00f3n Java. Como aplicaci\u00f3n Java se ejecuta en una m\u00e1quina virtual que le asigna por defecto un l\u00edmite de memoria para ejecutarse. Normalmente esa cantidad de memoria asignada por defecto es suficiente para la ejecuci\u00f3n del programa. No obstante es posible que para realizar tablas muy extensas esta memoria sea insuficiente.<\/p>\n<p>Para estos casos es posible ejecutar el cliente forzando a la m\u00e1quina virtual a que le asigne m\u00e1s memoria al programa. Esto se consigue ejecutando el programa desde la l\u00ednea de comandos con un par\u00e1metro indicando el m\u00e1ximo y el m\u00ednimo de memoria disponibles para el programa.<\/p>\n<ul>\n<li><strong>java -Xm256m -Xmx1024m \u2013jar AppletScada.jar<\/strong><\/li>\n<\/ul>\n<p>Como puede verse los par\u00e1metros -Xm y -Xmx asignan una cantidad m\u00ednima y m\u00e1xima al programa.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc simular un control interruptor?&#8221; tab_id=&#8221;1615896824788-ca9ac1fb-6965&#8243;][vc_column_text]Para simular el comportamiento de un interruptor (por ejemplo para actuar sobre una salida digital) necesita un control condicional y dos controles para forzar variable. El control condicional contendr\u00eda dos im\u00e1genes, una con una representaci\u00f3n de un interruptor abierto, con la condici\u00f3n de que la variable digital sea 1, y otra con la representaci\u00f3n de un interruptor cerrado, con la condici\u00f3n de que la variable digital sea 0.[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;1806&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743073257{margin-top: 20px !important;}&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;1808&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743091106{margin-top: 20px !important;}&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]Luego sobre la parte izquierda del control se coloca un control para forzar variable que ponga el valor de la salida digital a 1, y sobre la parte derecha se coloca otro control para forzar variable que ponga el valor de la salida a 0.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc afegir una animaci\u00f3 a l&#8217;SCADA?&#8221; tab_id=&#8221;1615896816728-42fe3365-8c6d&#8221;][vc_column_text]Para poder a\u00f1adir una peque\u00f1a imagen animada podr\u00e1 utilizar el control condicional combinado con la funci\u00f3n \u201csecond\u201d en la condici\u00f3n. En primer lugar, guarde las im\u00e1genes que componen la animaci\u00f3n mediante el gestor de im\u00e1genes. Supongamos que su animaci\u00f3n consta de una secuencia de 3 im\u00e1genes. Supongamos tambi\u00e9n que queremos que nuestra animaci\u00f3n cambie cada segundo. Para ello deberemos crear una f\u00f3rmula en la lista de f\u00f3rmulas de la pantalla SCADA que nos devuelva el m\u00f3dulo 3 de la funci\u00f3n \u201csecond\u201d (variar\u00e1 entre los valores, 0, 1 y 2). La funci\u00f3n es como sigue:<\/p>\n<p><strong>mod(second,3)<\/strong><\/p>\n<p>Supongamos que a esta funci\u00f3n la llamamos MOD. Ahora ya podemos definir un control condicional con 3 condiciones donde cada condici\u00f3n se muestra una de las im\u00e1genes que forman la animaci\u00f3n. A continuaci\u00f3n podemos ver las propiedades del control:[\/vc_column_text][vc_single_image image=&#8221;1810&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616743164570{margin-top: 20px !important;}&#8221;][vc_column_text]As\u00ed conseguiremos que cada segundo se muestre una de las im\u00e1genes que forman la animaci\u00f3n. Como puede intuirse, existen m\u00faltiples combinaciones a realizar y una gran variedad de posibilidades a explotar mediante esta t\u00e9cnica.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc simular un control de nivell?&#8221; tab_id=&#8221;1615896801575-532319c2-7b3e&#8221;][vc_column_text]Existen dos formas de realizar un control de nivel en una pantalla SCADA. La primera de ellas consiste en utilizar un control condicional, donde cada control es una imagen con un nivel diferente y donde cada condici\u00f3n indica qu\u00e9 debe cumplirse para alcanzar ese nivel. A continuaci\u00f3n se muestr\u00e1n algunas im\u00e1genes de un ejemplo concreto con sus condiciones:[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;1817&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743394822{margin-top: 20px !important;}&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\"><strong>[CVM K 1.VI1] == 215<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;1813&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743447080{margin-top: 20px !important;}&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\"><strong>[CVM K 1.VI1] == 221<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;1815&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743455698{margin-top: 20px !important;}&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\"><strong>[CVM K 1.VI1] == 224<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_column_text]Otra opci\u00f3n ser\u00eda dibujar el control de nivel en el fondo de la pantalla SCADA y utilizar diversos controles de bote de pintura para pintar la zona deseada. As\u00ed pues, podr\u00edamos dibujar en el fondo de pantalla algo como lo siguiente:[\/vc_column_text][vc_single_image image=&#8221;1819&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743499646{margin-top: 20px !important;}&#8221;][vc_column_text]La parte interna, aunque parezca toda del mismo color (blanco), no lo es y est\u00e1 dividida en cuadr\u00edculas con diferentes blancos indistinguibles entre si por el ojo humano (por ejemplo, es imposible distinguir entre el blanco RGB 255,255,255 y el blanco RGB 254,255,255).<\/p>\n<p>Luego ponemos sobre cada cuadro el bote de pintura con la condici\u00f3n deseada y tolerancia 0 para evitar que pinte los cuadros adyacentes, que son muy semejantes en color.[\/vc_column_text][vc_single_image image=&#8221;1821&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743534867{margin-top: 20px !important;}&#8221;][vc_column_text]Con esto conseguimos una barra de progreso (o control de nivel) que podemos configurar a nuestro antojo.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc canviar les propietats d&#8217;un control segons una condici\u00f3?&#8221; tab_id=&#8221;1615896786610-2dca3a1a-41c8&#8243;][vc_column_text]Las propiedades de un control no pueden cambiarse dependiendo de una condici\u00f3n. No obstante, puede simularse el cambio de dichas propiedades mediante un control condicional. As\u00ed, por ejemplo, si queremos que un texto cambie de color dependiendo de una condici\u00f3n a\u00f1adiremos un control condicional con dos controles de tipo texto totalmente iguales pero con color diferente y especificaremos que condiciones han de cumplirse para que se muestre cada uno. Igualmente puede cambiarse la orientaci\u00f3n, el tipo de letra, el tama\u00f1o, etc.<\/p>\n<p>Tambi\u00e9n puede hacerse que in control sea una imagen o un texto dependiendo de una condici\u00f3n usando, como en el caso anterior, el control condicional.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc con\u00e8ixer l&#8217;estat d&#8217;un dispositiu?&#8221; tab_id=&#8221;1615896833329-ec8e18f5-d9c3&#8243;][vc_column_text]Todos los dispositivos tienen una variable denominada STATUS que muestra el estado del dispositivo mediante un valor num\u00e9rico (por ejemplo, [CVM144.STATUS]) El significado de esta variable es el mismo para todos los dispositivo y puede utilizarse en las expresiones condicionales (ver ap\u00e9ndice de los tipos de variables para consultar sus posibles valores).[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc mostrar documents des d&#8217;una pantalla SCADA?&#8221; tab_id=&#8221;1615896843295-3c6886e5-b505&#8243;][vc_column_text]Para mostrar documentos previamente almacenados en el PC puede utilizar el control de ejecuci\u00f3n. S\u00ed desea mostrar un fichero PDF puede poner directamente el nombre del mismo (incluyendo la ruta completa) en el campo de programa de manera que al ejecutarse la pantalla y hacer clic sobre el control se abrir\u00e1 dicho fichero mediante el programa relacionado y definido en el sistema. Igualmente puede hacerse para cualquier tipo de fichero que tenga asociado alg\u00fan programa que lo abra (DOC, TXT, HTML, WAV, MP3, MPG, AVI, etc.)<\/p>\n<p><strong>Nota<\/strong>: Esta opci\u00f3n no funcionar\u00e1 en sistemas que no sean Windows ni a trav\u00e9s del Applet.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc mostrar documents en resposta a un succ\u00e9s?&#8221; tab_id=&#8221;1615896910975-ade82425-9013&#8243;][vc_column_text]Para poder producir un suceso en funci\u00f3n de alg\u00fan estado de uno o varios dispositivos utilice la variable STATUS de dichos dispositivos en la condici\u00f3n de activaci\u00f3n del suceso. Para consultar los posibles valores de la variable STATUS lea el ap\u00e9ndice de tipos de variables.<\/p>\n<p>Dado que los sucesos generan una serie de variables asociadas al mismo, podr\u00e1 incluso consultar cuantas veces se activ\u00f3 un suceso, cuantas se desactiv\u00f3, cuantas se reconoci\u00f3 y cuanto tiempo estuvo activado.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc obtenir un succ\u00e9s segons l&#8217;estat d&#8217;un dispositiu?&#8221; tab_id=&#8221;1615896891582-3c9a7b95-2ea6&#8243;][vc_column_text]Para producir un sonido en respuesta a un suceso puede a\u00f1adir una acci\u00f3n de ejecutar un programa externo e introducir en el campo de programa el fichero de sonido a reproducir (WAV, MP3, etc.) con su ruta correspondiente. Para que la acci\u00f3n surja efecto deber\u00e1 tener un programa que reproduzca este tipo de ficheros instalado en el sistema (por ejemplo, Windows Media Player, Sonique, Winamp, etc.)<\/p>\n<p>Si lo que se necesita es simplemente reproducir un pitido en el cliente, puede a\u00f1adir una acci\u00f3n asociada a dicho suceso que realice esta acci\u00f3n. Asimismo esta acci\u00f3n puede producirse al activarse, al reconocerse, al desactivarse o mientras est\u00e1 activo.[\/vc_column_text][vc_single_image image=&#8221;1823&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1616743665987{margin-top: 20px !important;}&#8221;][vc_column_text]<\/p>\n<p style=\"text-align: center;\"><strong>Ayuda para la acci\u00f3n de la alarma sonora en el cliente en respuesta a un suceso<\/strong><\/p>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc mostrar documents en resposta a un succ\u00e9s?&#8221; tab_id=&#8221;1615896836195-693aafdd-9dd3&#8243;][vc_column_text]De manera similar al punto anterior, a\u00f1ada una acci\u00f3n de ejecutar un programa externo e introduzca en el campo de programa el documento que desee mostrar (PDF, TXT, DOC, etc.) con la ruta correspondiente. Para que la acci\u00f3n surja efecto deber\u00e1 tener un programa que reproduzca este tipo de ficheros instalado en el sistema (por ejemplo, Microsoft Word, Adobe Acrobat Reader, etc.)[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc produir sons en resposta a un succ\u00e9s?&#8221; tab_id=&#8221;1615896944175-a5e6b611-f8c5&#8243;][vc_column_text]La aplicaci\u00f3n cliente de PowerStudio realiza muchas conexiones al servidor de forma continuada. En Windows se limitan los sockets (puertos) abiertos para establecer las conexiones y, adem\u00e1s, se mantienen inutilizables durante un tiempo determinado despu\u00e9s de ser liberados (WAIT). As\u00ed, por ejemplo, en Windows XP se permite por defecto a las aplicaciones de usuario disponer de los puertos que van del 1024 al 5000 y, tambi\u00e9n por defecto, un puerto queda en estado TIME_WAIT durante 4 minutos una vez cerrado antes de ser definitivamente liberado por el sistema operativo.<\/p>\n<p>En Windows es posible modificar esta pol\u00edtica modificando o creando dos claves del registro que definen este comportamiento. Para ello debe ejecutar la aplicaci\u00f3n regedit suministrada con todas las versiones de Windows. Las claves son:<\/p>\n<p><strong>MaxUserPort<\/strong><\/p>\n<p><strong>TcpTimedWaitDelay<\/strong><\/p>\n<p>Situadas en:<\/p>\n<p><strong>HKEY_LOCAL_MACHINE\\System\\CurrentControlSet\\Services\\Tcpip\\Parameters<\/strong><\/p>\n<p>Ambas claves son de tipo DWORD y deben ser creadas si no se encuentran en la ruta especificada. En la primera asignamos el n\u00famero de puerto m\u00e1ximo, que por defecto est\u00e1 en 5000, y lo ponemos por ejemplo a 20000 (en notaci\u00f3n decimal) y en la segunda ponemos el tiempo en segundos que queremos que un puerto se mantenga reservado despu\u00e9s de cerrarlo (lo ponemos a 30 por ejemplo, en notaci\u00f3n decimal). Hay que comprobar estos par\u00e1metros tanto en el ordenador servidor como en el cliente. Recuerde que debe reiniciar el PC para que los cambios tengan efecto.<\/p>\n<p>En otros sistemas operativos debe consultarse la forma particular de configurar este comportamiento.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;No puc connectar amb el motor o alguns equips TCP\/IP donen errors. En la consola Java apareix l&#8217;error: java.net.BindException: Address already in use: connect. Com puc solucionar-lo?&#8221; tab_id=&#8221;1615896898658-147b415c-47ca&#8221;][\/vc_tta_section][vc_tta_section title=&#8221;No puc crear pantalles SCADA ni informes ni definir successos. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896950969-765fa36a-fa5f&#8221;][vc_column_text]Usted tiene una versi\u00f3n de PowerStudio est\u00e1ndar. P\u00f3ngase en contacto con su distribuidor para adquirir una versi\u00f3n SCADA o Deluxe.[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][vc_column_text]<\/p>\n<h6 class=\"wrap-title\">COMUNICACIONS<\/h6>\n<p>[\/vc_column_text][vc_tta_accordion style=&#8221;modern&#8221; shape=&#8221;square&#8221; color=&#8221;white&#8221; c_icon=&#8221;chevron&#8221; active_section=&#8221;-1&#8243; el_class=&#8221;acordeon_preguntas_frecuentes&#8221;][vc_tta_section title=&#8221;No comunica algun equip. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896270415-c43e6666-e8be&#8221;][vc_column_text]Compruebe que el equipo est\u00e1 encendido y en un modo en el que puede comunicar, en particular aseg\u00farese de que no est\u00e1 en modo de configuraci\u00f3n o inici\u00e1ndose. Compruebe que el equipo est\u00e1 conectado al PC o a un conversor compatible y que el conexionado es correcto. Compruebe que no haya posibilidad de ning\u00fan tipo de interferencias en el camino que siguen los cables desde el dispositivo al PC o entre el dispositivo y el conversor. Si est\u00e1 conectado a un conversor compruebe que este \u00faltimo se encuentre correctamente conectado al PC. Compruebe que la red no est\u00e1 sobrecargada con un n\u00famero excesivo de dispositivos. Si el equipo se conecta mediante un conversor 232-485 aseg\u00farese de que los interruptores del mismo est\u00e1n en la posici\u00f3n correcta. Aseg\u00farese de que en el mismo bus de equipos no hay aparatos que comunican a distintas velocidades o con el mismo n\u00famero de dispositivo. Compruebe que el puerto del PC funciona correctamente.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;No comunica un conversor TCP2RS. Qu\u00e8 pot estar passant?&#8221; tab_id=&#8221;1615896299644-4885e2e1-abe6&#8243;][vc_column_text]Compruebe que el equipo est\u00e1 encendido y conectado a la red de comunicaciones. Compruebe que no haya posibilidad de ning\u00fan tipo de interferencias en el camino que siguen los cables desde el conversor al PC. Compruebe que el PC esta conectado correctamente a la red de comunicaciones y puede comunicar con otros equipos conectados a la red (por ejemplo con otro PC). Si esta utilizando un router, compruebe que el puerto de comunicaciones este redireccionado, en el router, a la direcci\u00f3n del conversor.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Com puc comunicar amb un conversor TCP2RS mitjan\u00e7ant un router?&#8221; tab_id=&#8221;1615896299262-dc82a028-dd76&#8243;][vc_column_text]Para comunicar con un conversor TCP2RS que se encuentra en una subred diferente de la red en la que se encuentra el software utilizando un router como elemento de conexi\u00f3n entre las dos redes como muestra la siguiente imagen:[\/vc_column_text][vc_single_image image=&#8221;1825&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616743877230{margin-top: 20px !important;}&#8221;][vc_column_text]Se deber\u00e1 a\u00f1adir el conversor TCP2RS de la siguiente manera:[\/vc_column_text][vc_single_image image=&#8221;1827&#8243; img_size=&#8221;full&#8221; css=&#8221;.vc_custom_1616743968196{margin-top: 20px !important;}&#8221;][vc_column_text]<\/p>\n<ol>\n<li>Introducir la direcci\u00f3n del router (192.168.120.201) en la casilla \u2018Direcci\u00f3n conversor\u2019<\/li>\n<li>Redireccionar el puerto \u201810001\u2019 y el \u201830718\u2019 en el router a la direcci\u00f3n del conversor (192.168.15.205) (ver manual del router)<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][\/vc_column][vc_column width=&#8221;1\/6&#8243;][\/vc_column][\/vc_row][vc_row el_class=&#8221;empresa-pasando acceso_contacto bloque&#8221;][vc_column][vc_raw_html]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[\/vc_raw_html][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;banner_pagina_texto&#8221; css=&#8221;.vc_custom_1662460257542{background-image: url(https:\/\/circutor.com\/wp-content\/uploads\/2022\/09\/FSB_FAQS.jpg?id=28416) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_column css=&#8221;.vc_custom_1605620904006{padding-top: 0px !important;}&#8221;][vc_row_inner el_class=&#8221;breadcrumb&#8221;][vc_column_inner][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text] Soluci\u00f3 a les preguntes m\u00e9s habituals En aquesta p\u00e0gina pots trobar resposta a temes que et poden interessar. Per exemple, com configurar les comunicacions d&#8217;un CVM, qu\u00e8 fer si la mesura no \u00e9s correcta, etc.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_class=&#8221;bloque&#8221;][vc_column][vc_column_text] RESPOSTES [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"parent":26944,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Preguntes freq\u00fcents - CIRCUTOR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/\" \/>\n<meta property=\"og:locale\" content=\"ca_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Preguntes freq\u00fcents - CIRCUTOR\" \/>\n<meta property=\"og:description\" content=\"[vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;banner_pagina_texto&#8221; css=&#8221;.vc_custom_1662460257542{background-image: url(https:\/\/circutor.com\/wp-content\/uploads\/2022\/09\/FSB_FAQS.jpg?id=28416) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_column css=&#8221;.vc_custom_1605620904006{padding-top: 0px !important;}&#8221;][vc_row_inner el_class=&#8221;breadcrumb&#8221;][vc_column_inner][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text] Soluci\u00f3 a les preguntes m\u00e9s habituals En aquesta p\u00e0gina pots trobar resposta a temes que et poden interessar. Per exemple, com configurar les comunicacions d&#8217;un CVM, qu\u00e8 fer si la mesura no \u00e9s correcta, etc.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_class=&#8221;bloque&#8221;][vc_column][vc_column_text] RESPOSTES [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/\" \/>\n<meta property=\"og:site_name\" content=\"CIRCUTOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/CIRCUTOR.ES\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-12T13:17:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1299\" \/>\n\t<meta property=\"og:image:height\" content=\"354\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@circutor\" \/>\n<meta name=\"twitter:label1\" content=\"Temps estimat de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"28 minuts\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/circutor.com\/#organization\",\"name\":\"Circutor\",\"url\":\"https:\/\/circutor.com\/\",\"sameAs\":[\"https:\/\/www.instagram.com\/circutor_es\",\"https:\/\/www.linkedin.com\/company\/circutor\",\"https:\/\/www.youtube.com\/user\/CIRCUTORoficial\",\"https:\/\/www.facebook.com\/CIRCUTOR.ES\",\"https:\/\/twitter.com\/circutor\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ca\",\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"contentUrl\":\"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png\",\"width\":512,\"height\":128,\"caption\":\"Circutor\"},\"image\":{\"@id\":\"https:\/\/circutor.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/circutor.com\/#website\",\"url\":\"https:\/\/circutor.com\/\",\"name\":\"CIRCUTOR\",\"description\":\"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica\",\"publisher\":{\"@id\":\"https:\/\/circutor.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/circutor.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"ca\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/\",\"url\":\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/\",\"name\":\"Preguntes freq\u00fcents - CIRCUTOR\",\"isPartOf\":{\"@id\":\"https:\/\/circutor.com\/#website\"},\"datePublished\":\"2023-07-10T10:38:41+00:00\",\"dateModified\":\"2023-07-12T13:17:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/#breadcrumb\"},\"inLanguage\":\"ca\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/circutor.com\/ca\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Suport\",\"item\":\"https:\/\/circutor.com\/ca\/suport\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Preguntes freq\u00fcents\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Preguntes freq\u00fcents - CIRCUTOR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/","og_locale":"ca_ES","og_type":"article","og_title":"Preguntes freq\u00fcents - CIRCUTOR","og_description":"[vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;banner_pagina_texto&#8221; css=&#8221;.vc_custom_1662460257542{background-image: url(https:\/\/circutor.com\/wp-content\/uploads\/2022\/09\/FSB_FAQS.jpg?id=28416) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_column css=&#8221;.vc_custom_1605620904006{padding-top: 0px !important;}&#8221;][vc_row_inner el_class=&#8221;breadcrumb&#8221;][vc_column_inner][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text] Soluci\u00f3 a les preguntes m\u00e9s habituals En aquesta p\u00e0gina pots trobar resposta a temes que et poden interessar. Per exemple, com configurar les comunicacions d&#8217;un CVM, qu\u00e8 fer si la mesura no \u00e9s correcta, etc.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row el_class=&#8221;bloque&#8221;][vc_column][vc_column_text] RESPOSTES [&hellip;]","og_url":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/","og_site_name":"CIRCUTOR","article_publisher":"https:\/\/www.facebook.com\/CIRCUTOR.ES","article_modified_time":"2023-07-12T13:17:40+00:00","og_image":[{"width":1299,"height":354,"url":"https:\/\/circutor.com\/wp-content\/uploads\/2022\/07\/Circutor_Logo_Color.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@circutor","twitter_misc":{"Temps estimat de lectura":"28 minuts"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/circutor.com\/#organization","name":"Circutor","url":"https:\/\/circutor.com\/","sameAs":["https:\/\/www.instagram.com\/circutor_es","https:\/\/www.linkedin.com\/company\/circutor","https:\/\/www.youtube.com\/user\/CIRCUTORoficial","https:\/\/www.facebook.com\/CIRCUTOR.ES","https:\/\/twitter.com\/circutor"],"logo":{"@type":"ImageObject","inLanguage":"ca","@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/","url":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","contentUrl":"https:\/\/circutor.com\/wp-content\/uploads\/2020\/09\/CIR_LOGO_RED.png","width":512,"height":128,"caption":"Circutor"},"image":{"@id":"https:\/\/circutor.com\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/circutor.com\/#website","url":"https:\/\/circutor.com\/","name":"CIRCUTOR","description":"Soluciones para la eficiencia energ\u00e9tica el\u00e9ctrica","publisher":{"@id":"https:\/\/circutor.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/circutor.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"ca"},{"@type":"WebPage","@id":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/","url":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/","name":"Preguntes freq\u00fcents - CIRCUTOR","isPartOf":{"@id":"https:\/\/circutor.com\/#website"},"datePublished":"2023-07-10T10:38:41+00:00","dateModified":"2023-07-12T13:17:40+00:00","breadcrumb":{"@id":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/#breadcrumb"},"inLanguage":"ca","potentialAction":[{"@type":"ReadAction","target":["https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/circutor.com\/ca\/suport\/preguntes-frequents\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/circutor.com\/ca\/"},{"@type":"ListItem","position":2,"name":"Suport","item":"https:\/\/circutor.com\/ca\/suport\/"},{"@type":"ListItem","position":3,"name":"Preguntes freq\u00fcents"}]}]}},"_links":{"self":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/pages\/39887"}],"collection":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/comments?post=39887"}],"version-history":[{"count":0,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/pages\/39887\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/pages\/26944"}],"wp:attachment":[{"href":"https:\/\/circutor.com\/ca\/wp-json\/wp\/v2\/media?parent=39887"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}